Section 2: PCB Installation and Startup
Analog Trunk (4COIU-S) PCB (Figure 2-11)
The Analog Trunk (COIU-S) PCB provides:
●
4 analog loop start line/trunk circuits - no ground start is provided
●
4 trunk status LEDs
●
4 Caller ID Circuits
●
1 Power Failure Transfer Circuit
●
1 PCB status LED
The CN5 and CN7 connectors each provide connection to 2 analog trunk ports, which are polarity sensitive
(tip to tip, ring to ring). The power failure circuit, however, is not polarity sensitive. A maximum of 2
4COIUs per system is allowed.
LED Indications
LD5
(PCB Status)
LD1 - LD4
2-24 ◆ Section 2: PCB Installation and Startup
LED
Function
Indicates the status of
the PCB.
Indicates the status of
the lines.
LED Status
Green On
Initializing
Green Flashing
Initialization problem
(slow flash)
occurred during self-check.
Green Flashing
Operating normally
(100ms On/Off)
Green Off
Downloading
Red On
Line in use
Red Off
Line idle
Operation Status