Detailed Description
2.9 Mode group, channel, program operation, reset response (K1)
2.9.5
Signals to axis/spindle (DB31, ...)
DB31, ...
DBX10.0
REPOSDELAY
Edge evaluation: no
Signal state 1 or
The REPOS offset of the axis is first applied with its next programming.
edge change
0 → 1
Signal state 0 or
There is no REPOS offset.
edge change
1 → 0
Special cases,
The signal is not relevant for path axes.
errors, ......
Corresponds to ....
DB21, ... DBX31.0 - DBX31.2 (REPOSPATHMODE0-2)
DB31, ... DBX70.2 (REPOS Delay Ackn)
DB31, ... DBX72.0 (REPOSDELAY)
2.9.6
Signals from axis/spindle (DB31, ...)
DB31, ...
DBX70.0
REPOS offset
Edge evaluation: no
Signal state 1 or
A REPOS offset must be applied for the appropriate axis.
edge change
0 → 1
Signal state 0 or
No REPOS offset need be applied for the appropriate axis.
edge change
1 → 0
Corresponds to ....
DB31, ... DBX70.1 (REPOS offset valid)
DB31, ...
DBX70.1
REPOS offset valid
Edge evaluation: no
Signal state 1 or
The range of validity of the REPOS offset is indicated with the value 1.
edge change
The REPOS offset was calculated to be valid.
0 → 1
Signal state 0 or
A value of zero indicates that the REPOS offset was calculated to be invalid.
edge change
1 → 0
Application
Updating the REPOS offset in the range of validity:
example(s)
Between SERUPRO end and start, the axis can be moved in JOG mode with a mode change. The
user moves the REPOS offset to the zero value.
Corresponds to ....
DB31, ... DBX70.0 (REPOS offset)
106
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Basic logic functions: NC/PLC interface signals (Z1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0