Online Calibration Of Multipoint Adjustment Channels - Bosch C60 Manual

Hide thumbs Also See for C60:
Table of Contents

Advertisement

10.3 Online calibration of multipoint adjustment
Bosch Motorsport
channels
Example: measurement of wheel force
– Physical property 'wheel force' not directly measureable
– Load transfer through suspension kinematics
– Physical value at sensor position defined by vehicle
– Curve definition by online adjustment at vehicle
Force at sensor
Force at wheel
1.
Create a multipoint adjustment measurement channel. To create a multipoint channel,
see chapter 'Configuring a multipoint adjustment'.
2.
Download the configuration on the C 60. To connect the C 60 to RaceCon, see
chapter 'Setting up a new RaceCon Project'.
3.
Click on the desired channel in the C 60 Project Tree.
4.
Double-click on a measurement channel in the Data Area to open the online view.
Click to open
measurement
channels in data
view
Double-click
to open
online view
5.
Click on 'Calibrate adjustment points' to open calibration window.
6.
Apply the desired physical condition to the sensor (e.g. by applying a force on the
wheel).
7.
Enter the physical value in the value column of the desired calibration point
(e.g. 745 N).
Data_Logger_C_60_Manual
Online Measurement and Calibration | 10
Click to open
calibration
window
Analog and physical
value
65 / 100