Technical data and limitations – PACi systems –
AHU Kit
Outdoor unit – PACi Elite
Nominal cooling capacity
Nominal heating capacity
Piping connections
Liquid pipe
Gas pipe
Ambient temperature
Cooling (Min / Max) °C DB
Heating (Min / Max) °C WB
AHU unit under "standard conditions"
Air volume fl ow
Cooling (Min / Max) m³/h
Air intake temperature
Cooling (Min / Max) °C DB
1
Heating (Min / Max) °C DB
AHU DX coil heat exchanger volume Min / Max
Heat exchanger face area
Min / Max
Piping length
Min / Max
Precharged length (R410A)
Max
Additional refrigerant charge (R410A) due to extended
piping length
AHU unit under "special conditions A
"
2
Air volume fl ow,
Cooling (Min / Max) m³/h
subject to restrictions
2
Air intake temperature
Cooling (Min / Max) °C DB
1
Heating (Min / Max) °C DB
AHU unit under "special conditions B
"
3
AHU DX coil heat exchanger volume,
Min / Max
subject to restrictions
3
Additional refrigerant charge (R410A) due to larger heat
exchanger volume
Max. additional refrigerant charge (R410A)
Max. pipe length
Max. ambient temp. for pump down
480 500 540 700 720 800 840 900 960 1000 1080 1140 1200 1450 1500 1600 1680 1800 1980 2100 2160 2280 2400 2500 2600 2700 3500 3960 4000 4300 4440 4500 5000 5400
Outdoor unit
U-60PEY2E5
U-71PEY2E5
U100-PEY1E5/8
U125-PEY1E5/8
U140-PEY1E8
U-50PE2E5
U-60PE2E5
U-71PE1E5/8
U-100PE1E5/8
U-125PE1E5/8
U-140PE1E5/8
U-200PE2E8
U-250PE2E8
Maximum allowed air volume fl ow
under "Standard conditions"
1 Air intake temperature entering the AHU DX coil heat exchanger
2 Special conditions A: Using an AHU unit with a higher maximum allowed air volume fl ow is subject to a restriction of
the "Air intake temperature" to 30 °C DB (instead of 32 °C WB under standard conditions).
3 Special conditions B: Using an AHU DX coil heat exchanger with a larger volume is subject to the following
restrictions:
Note: The AHU DX coil must be designed according to Panasonic specifi cation.
U-71PE1E8A
kW
7.1
kW
8.0
Inch (mm) 3/8" (9,52)
Inch (mm) 5/8" (15,88)
-10 / 43
-20 / 15
720 / 1,500
18 / 32
°C WB
13 / 23
16 / 30
dm
– / 1.8
3
m
– / –
2
m
5 / 50
m
30
g/m
50
720 / 1,800
18 / 30
°C WB
13 / 23
16 / 30
dm
– / 2.2
3
kg/dm
0.9
3
kg
0.36
m
40
°C
35
Higher maximum allowed air volume fl ow under "Special conditions A
Maximum allowed air intake temperature at AHU DX coil heat exchanger in cooling mode is restriced to 30 °C DB.
an additional refrigerant charge (R410A), which is required irrespective of an additional refrigerant
charge which might be needed due to an extended piping length (see calculation example below)
AND a reduced maximum pipe length
AND an ambient air temperature limit above which it may not be possible to pump down the com-
plete refrigerant charge (including all additional refrigerant) into the outdoor unit.
R410A
PAW-280PAH2(L/M)
U-100PE1E8A
U-125PE1E8A
U-140PE1E8A
10.0
12.5
14.0
11.2
14.0
16.0
3/8" (9,52)
3/8" (9,52)
3/8" (9,52)
5/8" (15,88)
5/8" (15,88)
5/8" (15,88)
-10 / 43
-10 / 43
-10 / 43
-20 / 15
-20 / 15
-20 / 15
840 / 1,980
1,140 / 2,100
1,140 / 2,160
18 / 32
18 / 32
18 / 32
13 / 23
13 / 23
13 / 23
16 / 30
16 / 30
16 / 30
1.7 / 2.1
1.7 / 2.1
1.7 / 2.1
0.43 / 0.51
0.43 / 0.51
0.43 / 0.51
5 / 50
5 / 50
5 / 50
30
30
30
50
50
50
840 / 2,400
1,140 / 2,600
1,140 / 2,700
18 / 30
18 / 30
18 / 30
13 / 23
13 / 23
13 / 23
16 / 30
16 / 30
16 / 30
1.7 / 3.0
1.7 / 3.0
1.7 / 3.0
0.9
0.9
0.9
0.81
0.81
0.81
30
30
30
25
25
25
Air volume fl ow m³/h
":
2
Product description
(cont.)
U-200PE2E8A
U-250PE2E8A
19.5
25.0
22.4
28.0
3/8" (9,52)
1/2" (12,7)
1" (25,4)
1" (25,4)
-15 / 43
-15 / 43
-20 / 15
-20 / 15
1,680 / 3,960
2,280 / 4,440
18 / 32
18 / 32
13 / 23
13 / 23
16 / 30
16 / 30
2.3 / 4.3
2.7 / 4.3
0.54 / 1.0
0.66 / 1.0
5 / 70
5 / 70
30
30
50
80
1,680 / 4,300
2,280 / 5,400
18 / 30
18 / 30
13 / 23
13 / 23
16 / 30
16 / 30
2.3 / 5.7
2.7 / 7.1
0.9
0.9
1.25
2.51
n/a
n/a
n/a
n/a
35