Comparing parameter settings
The current parameter values of a drive object can be compared with another parameter set
using the comparison function in the parameter view. The following comparisons are
possible:
● Offline - Factory setting
● Online - Offline
● Online - Factory setting
Comparing parameters
To compare the parameters of the drive object with another parameter set, proceed as
follows:
1. Open the parameter view for the device whose parameters you want to compare.
2. Click the black arrow icon of the
with another data set" button.
A selection list containing the comparison options opens:
– Offline - Factory setting (default setting in offline mode)
– Online - Offline (default setting in online mode)
– Online - Factory setting
3. Select a comparison option.
The selected comparison option is executed as follows:
– The "Comparison" column is displayed.
– The comparison result of the selected comparison option is displayed by icons in the
Quick compare depends on parameterization mode:
1. Click the scales icon on the
Result:
– Offline mode: By default, the parameters are compared with the factory settings.
– Online mode: By default, the parameters are compared with the offline settings.
70
"Comparison" column.
"Compare current parameters of this drive object
button.
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
Commissioning with Startdrive