Work preparation
3.1 Flexible NC programming
Note
Compatibility of units
When using variables (assignment, comparison, calculation, etc.) the compatibility of the units
involved is not checked. Should conversion be required, this is the sole responsibility of the
user / machine manufacturer.
See also
Variables (Page 389)
3.1.1.10
Attribute: Access rights (APR, APW, APRP, APWP, APRB, APWB)
Designation
The designation of the access attribute AP... comprises:
1. A: Access
2. P: Protection
3. R / W: Read / Write
4. P / O: Program / BTSS (OPI)
Access rights / access levels
The following access levels, which have to be specified during programming, correspond to the
access rights:
Access right
System password
Machine manufacturer password
Service password
End user password
Key-operated switch position 3
Key-operated switch position 2
Key-operated switch position 1
Key-operated switch position 0
Definition (DEF) of user data
Access rights (APR.../APW...) can be defined for the following data:
● Global user data (GUD)
412
Protection level
0
1
2
3
4
5
6
7
Programming Manual, 12/2019, 6FC5398-2EP40-0BA0