8 | Technical Data
46 / 112
RS232
Configuration via RaceCon
Mechanical Data
Size
Weight
Protection Classification
Operating temperature internal
Max. vibration
Electrical Data
Supply voltage
Inputs
Analog channels
Input range
Resolution
Switchable pull up resistor
Wheel speed inputs
Outputs
Sensor supply 5 V ± 1 % (250 mA)
Sensor supply 10 V ± 1 % (250 mA)
Sensor supply U_Bat 250 mA
Sensor ground
Optional Upgrades
USB_DATA
Adapter cable to USB-Port
Adapter for wiring harness
CCP_MASTER
ETHER_TELE
FULL_LOG_2
I_O EXTENS
Connectors and Wires
Motorsport connector on logger
Data Logger C 70 Manual
Telemetry, GPS
Over Ethernet or MSA-Box II
151 x 126 x 25.5 mm
450 g
IP54 to DIN 40050, Section 9, Issue 2008
-20 to 85°C
Vibration profile 1 (see Appendix or
www.bosch-motorsport.com)
5 to 18 V
4 standard, additional 12 optional
0 to 5 V
12 bit
For all ANA_IN
4 Hall-effect or DF11, switchable
2
1
1
4
USB-Port unlocked (Rugged USB flash
drive Bosch File System (BFS) format in-
cluded, works with Bosch File System
(BFS) preformatted USB Flash drive only)
included in Upgrade USB_DATA
included in Upgrade USB_DATA
CCP-Master (ASAP2 file from ECU manu-
facturer required
LTE Ethernet Telemetry
Enable full logging performance of 1 GB
partition 2
Enable additional 12 analog input chan-
nels
AS-216-35 PN