Technical Data
7.1.2 Input and Output Voltage
Input voltage
VAU 01.1U
Nominal input voltage
Input voltage range
Emitted interference and surge immunity
Current consumption for U
Input fuse
Switch-on threshold
Switch-off threshold
Max. power consumption
Reverse voltage protection
Tab. 7-2: Input voltage 24 V
VAU 01.1S
Nominal input voltage
Input voltage range
Emitted interference and surge immunity
Current consumption for U
Input fuse
Voltage rise of the supply voltage when switching
on
Voltage rise of the supply voltage when switching
off
Switch-on threshold
Switch-off threshold
Max. power consumption
Reverse voltage protection
Tab. 7-3: Input voltage 24 V
10/53
N
N
DC 24 V (use a 24 V power supply unit according
to DIN EN 60742, classification VDE 0551, for ex-
ample the power supply unit VAP01.1H-
W23-024-010-NN, part number R911171065)
DC 24 V +20 %, -15 %
U
= 35 V (for t < 100 ms)
max
Max. 12 A (2 A for charging the battery)
No
22 V ±5 %
19 V ±5 %
288 W (48 W for charging the battery)
Yes
DC 24 V (use a 24 V power supply unit according
to DIN EN 60742, classification VDE 0551, for ex-
ample the power supply unit VAP01.1H-
W23-024-010-NN, part number R911171065)
DC 24 V +20 %, -15 %
U
= 35 V (for t < 100 ms)
max
Max. 12 A (2 A for charging the battery)
No
Max. 500 ms (0 V to U
)
N
Max. 500 ms (U
to 0 V)
N
15.5 V ±5 %
20.2 V ±5 %
288 W (48 W for charging the battery)
No
DOK-SUPPL*-VAU*01.1X**-IT02-EN-P