NEC UNIVERGE SV8300 Command Manual page 429

Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

COMMAND CODE TITLE:
42
KIND OF SYSTEM COUNTER/PAD DATA
191
Setting of PAD data from a station/trunk to a
Conference Trunk for a Conference Trunk
connection
194
Restriction of number of password entries
when Protection Mode is canceled
NOTE:
When entering incorrect password for the number of times set by this command, DT700 Series will be
in password lock state.
195
Time to lock the DT700 Series when number
of password entries exceeded the limit
NOTE:
When the DT700 Series is in password lock state, a password entry is restricted until the time set by
this command is elapsed.
198
Volume Control (Side Tone level) of DT300/
DT700 Series
NOTE:
For the volume control (Side tone level) of the Multiline Terminal/DESKCON, set the data by
CM42>68.
SYSTEM COUNTER DATA/PAD DATA
SETTING DATA
00
-45 dB
(1 dB increment)
44
-1 dB
45
0 dB
46
+1 dB
(1 dB increment)
+18 dB
63
NONE
-10 dB
+: Gain
- : Loss
00
No limit
01
1 time
99
99 times
NONE
3 times
00
Not unlocked
01
1 minute
99
99 minutes
NONE
10 minutes
00
-54 dB
01
-48 dB
32
-18 dB
NONE
-12 dB
[For
EU]/
-18 dB
[Other than EU]
3-373
CM42
: Default
REMARKS
CM42>68
Continued on next page
NWA-033623-001 Rev.8.1
91ch3004.fm
JUNE/15/2011

Advertisement

Table of Contents
loading

Table of Contents