GE UR Series Instruction Manual page 380

Line differential relay
Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 16 of 38)
ADDR
REGISTER NAME
5A50
...Repeated for module number 6
5A60
...Repeated for module number 7
5A70
...Repeated for module number 8
5A80
...Repeated for module number 9
5A90
...Repeated for module number 10
B
5AA0
...Repeated for module number 11
5AB0
...Repeated for module number 12
Neutral TOC (Read/Write Grouped Setting) (6 modules)
5B00
Neutral TOC1 Function
5B01
Neutral TOC1 Signal Source
5B02
Neutral TOC1 Input
5B03
Neutral TOC1 Pickup
5B04
Neutral TOC1 Curve
5B05
Neutral TOC1 Multiplier
5B06
Neutral TOC1 Reset
5B07
Neutral TOC1 Block
5B08
Neutral TOC1 Target
5B09
Neutral TOC1 Events
5B0A
Reserved (6 items)
5B10
...Repeated for module number 2
5B20
...Repeated for module number 3
5B30
...Repeated for module number 4
5B40
...Repeated for module number 5
5B50
...Repeated for module number 6
Neutral IOC (Read/Write Grouped Setting) (12 modules)
5C00
Neutral IOC1 Function
5C01
Neutral IOC1 Signal Source
5C02
Neutral IOC1 Pickup
5C03
Neutral IOC1 Delay
5C04
Neutral IOC1 Reset Delay
5C05
Neutral IOC1 Block
5C06
Neutral IOC1 Target
5C07
Neutral IOC1 Events
5C08
Reserved (8 items)
5C10
...Repeated for module number 2
5C20
...Repeated for module number 3
5C30
...Repeated for module number 4
5C40
...Repeated for module number 5
5C50
...Repeated for module number 6
5C60
...Repeated for module number 7
5C70
...Repeated for module number 8
5C80
...Repeated for module number 9
5C90
...Repeated for module number 10
5CA0
...Repeated for module number 11
5CB0
...Repeated for module number 12
Ground TOC (Read/Write Grouped Setting) (6 modules)
5D00
Ground TOC1 Function
5D01
Ground TOC1 Signal Source
5D02
Ground TOC1 Input
5D03
Ground TOC1 Pickup
5D04
Ground TOC1 Curve
5D05
Ground TOC1 Multiplier
5D06
Ground TOC1 Reset
5D07
Ground TOC1 Block
B-24
RANGE
0 to 1
0 to 5
0 to 1
0 to 30
0 to 14
0 to 600
0 to 1
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 30
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 1
0 to 30
0 to 14
0 to 600
0 to 1
0 to 65535
L90 Line Differential Relay
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
---
1
F167
---
1
F122
pu
0.001
F001
---
1
F103
0 (IEEE Mod Inv)
---
0.01
F001
---
1
F104
0 (Instantaneous)
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
---
1
F122
pu
0.001
F001
---
1
F103
0 (IEEE Mod Inv)
---
0.01
F001
---
1
F104
0 (Instantaneous)
---
1
F300
GE Power Management
DEFAULT
0 (Disabled)
0 (SRC 1)
0 (Phasor)
1000
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
1000
0
0
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
0 (Phasor)
1000
100
0