2.10

Commissioning of power units connected in parallel

During commissioning, power units connected in parallel are treated like a power unit on the
line or motor side. With parallel connection, the parameter display for the actual values
changes only slightly. Suitable "total values" are derived from the individual values of the
power units.
Only power units in the "chassis" format are released for a parallel connection:
● Infeeds
● Motor Modules in "Vector" control mode
When commissioning the power units for the first time, activate the parallel connection via
the wizards in STARTER. Select the parallel connection when selecting the power unit
(infeed and/or Motor Module) according to the following diagrams as option:
Commissioning Manual
Commissioning Manual, (IH1), 01/2012, 6SL3097-4AF00-0BP2
Press the "P" key for approx. 5 sec, 41 is displayed. After pressing the "O" key, the display
jumps to 31 - and the drive is now ready. 10 is displayed in DO = 1.