Acceptable value range: X.XXXXX Degrees
XDIM=<xdim> Read Only.Yard Shape X Dimension miles
Acceptable value range: X.XXXXX Miles
YDIM=<ydim> Read Only.Yard Shape Y-Dimension miles
Acceptable value range: X.XXXXX Miles
COUNT=<count> Read Only. Number of cached yard info
Acceptable value range (8bits integer): -128 to 127
CMD=<cmd> If set to 0, the command executes normally. If <cmd> is set to 1, the
command reports all settings in a format that may be copied into a configuration
script.

4 Access Point Menu Interface

The COM1 console of the access point can be accessed using a serial terminal emulator program such
as HyperTerminal, Putty, or ucon. The default settings are: baud rate 19200, no parity, 8 data bits, and
1 stop bit. The pins for this port are listed in section 2.1.2. In some cases, this port is used for binary
data and is not escapable to the login prompt. In this case, you can watch the boot sequence of the
Access Point using a terminal emulator. During this sequence, the IP address of the unit is reported.
Once you have identified the IP address, you can access the menu via Telnet. To begin using the AP
menu, login with the administrator user name and password.

4.1 Login Screen

Availability: Repeater and LCU
05-XXXXA01 Version 3 Draft
Page 50 of 79