4.5.2
Configuration
You can make the following settings in the "Configuration" window:
Figure 4-3
● Assigning drive objects (p10010)
Sets the drive object number for the existing drives.
● Drive groups (p10011)
Sets the drive group for the existing drives.
● Discrepancy time F-DI (p10002)
The signal states at the two terminals of an F-DI are monitored in order to determine whether
these have assumed the same logical state within the discrepancy time.
Note
Discrepancy time
The discrepancy time must be set so that it is always shorter than the smallest expected
switching interval of the signal at the F-DIs.
Safety Integrated
Function Manual, 10/2015, 6FC5397-3EP40-5BA3
...
Press the "<< Back" softkey to exit the view of the checksums.
TM54F configuration
Commissioning - TM54F
4.5 Configuring the TM54F
103