VACUUM LEAK TEST PROCESS
High side inlet and low side inlet solenoids are activated to equalize high and low sides of system being serviced.
Unit checks low-side transducer for rise in vacuum. If the unit sees a rise of 338 mbar (10 in Hg) within 5 minutes
time, the vacuum leak test will fail (this is not a service menu test.)
Figure 4-14. Vacuum Leak Test
94
SP00D00609