16.2

AT+CPBR Read from Phonebook

serves to read one or more entries from the phonebook selected with AT command AT+CPBS.
AT+CPBR
The
test command returns the location range supported by the current phonebook storage, the maxi-
AT+CPBR
mum length of
<number>
Note: Length information may not be available while SIM storage is selected. If storage does not offer format
information, the format list contains empty parenthesizes.
The
write command determines the phonebook entry to be displayed with
AT+CPBR
range from
<location1>
will be displayed.
<location1>
If no entries are found at the selected location "OK" will be returned.
Syntax
Test Command
AT+CPBR=?
Response(s)
+CPBR: (1-<maxloc>), <nlength>,
OK
+CME ERROR
Write Command
AT+CPBR=<location1>[, <location2>]
Response(s)
[+CPBR: <location1>, <number>, <type>, <text>]
[+CPBR: <location2>, <number>, <type>, <text>]
OK
+CME ERROR
Reference(s)
GSM 07.07, GSM 11.11
Parameter Description
(num)
<location1>
The first (lowest) location number within phonebook memory where to start reading. The maximum range sup-
ported by the current phonebook is given in the test command response.
If
exceeds the upper bound
<location1>
respond with "+CME ERROR: invalid index".
(num)
<location2>
The last (highest) location number within phonebook memory where to stop reading. The maximum range sup-
ported by the current phonebook is given in the test command response.
If both
and
<location1>
loc>, the list of entries will be output and terminated with "OK".
If
exceeds the range indicated by the test command parameter <maxloc>, the list of entries will
<location2>
be output but terminated with "+CME ERROR: invalid index".
(str)
<number>
Phone number in format specified by <type>, it may be an empty string.
MC55_ATC_V04.00
Confidential / Released
field and the maximum length of
to <location2>. Hence, if no
<tlength>
<maxloc>
are in the range indicated by the test command parameter
<location2>
Page 382 of 475
field.
<text>
<location2>
PIN
ASC0 ASC1
MUX1
%
%
%
%
(as indicated by the test command), command will
or a location
<location1>
is given only the entry at
MUX2
MUX3 Charge
%
%
!
!
Last
!
<max-
3/17/06