HUAWEI MU609 HSPA Mini PCIe Module
Hardware Guide
4.3 Conducted RF Measurement
4.3.1 Test Environment
Test instrument
Power supply
RF cable for testing
4.3.2 Test Standards
Huawei modules meet 3GPP test standards. Each module passes strict tests at the
factory and thus the quality of the modules is guaranteed.
4.4 Conducted Rx Sensitivity and Tx Power
4.4.1 Conducted Receive Sensitivity
The conducted receive sensitivity is a key parameter that indicates the receiver
performance of MU609 module. The conducted receive sensitivity refers to the
weakest signal that the module at the antenna port can receive. The BER must meet
the 3GPP protocol requirements in the case of the minimum signal.
Table 4-2 lists the typical tested values of the MU609 module.
Table 4-2 MU609 module conducted Rx sensitivity (Unit: dBm)
Band
GSM 850
GSM 900
DCS 1800
PCS 1900
WCDMA Band 1 Main Rx
WCDMA Band 2 Main Rx
WCDMA Band 5 Main Rx
WCDMA Band 8 Main Rx
Issue 03 (2014-12-04)
R&S CMU200
KEITHLEY 2306
L08-C014-350 of DRAKA COMTEQ or Rosenberger
Cable length: 29 cm
The compensation for different frequency bands relates to the cable and the test
environment.
The instrument compensation needs to be set according to the actual cable conditions.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Typical Value
Note
–109
BER Class II < 2.44%
–109.5
BER Class II < 2.44%
–108
BER Class II < 2.44%
–108
BER Class II < 2.44%
–109.5
BER < 0.1%
–109
BER < 0.1%
–110.5
BER < 0.1%
–111
BER < 0.1%