80000437 Issue 1 06/18
230V Fan Range
Installation and Operating Guide
iCON 15 – 72683501
iCON 30 – 72591601
iCON 60 – 72591701
Electrical installation
Optional modules for iCON 230V
Wiring for control modules with no external switching:
Wiring for control modules with external switching:
Wiring and installation of iCON modules can be also found in
the Installation an Operation Guide included within the module
packaging (optional, see www.airflow.com for details).
Page 5 of 16
Fan dimensions
Model
A
B
C
D
iCON 15
197
108.5
67.5
100
Model
A
B
C
D
E
F
G
iCON 30 (R)
225
144
101
97
43
51
20
iCON 30 (S)
225
144
92
97
-
-
-
iCON 60 (R)
280
165
110
148
55
38
20
iCON 60 (S)
280
165
80
148
-
-
-
Page 2 of 16
Mechanical installation
Cable entry
Cable clamp
Module
locating block
iCON fans can be recessed in a wall or ceiling (iCON 30 and
60 are also supplied with surface mounting kit). See pages 8-
10 for details.
Always ensure free running of the fan impeller and that duct
connections are not over tightened to the fan outlet spigot.
Fix the sealed grommet supplied into the cable entry hole.
Pierce the grommet to allow the mains cable to be pulled
through while maintaining the integrity of the seal.
Airflow Developments recommends that rigid ducting is used
where possible instead of flexible ducting, this will ensure
maximum performance.
Before carrying out the installation see pages 11&12 for
best practise recommendations.
Important
Precautions must be taken to avoid the back-flow of gases into
the room from the open flue of gas or other fuel-burning appli-
ances.
Page 6 of 16
Range overview
Airflow® iCON® 230V fans are available in three model sizes
and can be fitted to a wall or ceiling.
Air flow
Power
Part no.
Model
[l/s / m
3
/h]
[W]
72683501
iCON 15
19 / 69
9.4
72591601
iCON 30
32 / 117
26.4
72591701
iCON 60
78 / 280
66.3
iCON 15 -100mm axial fan
iCON 30 -100mm mixed-flow fan
iCON 60 -150mm mixed-flow fan
E
The iCON range can be used as a simple extract fan oper-
40
ated by a remote switch (standard), or can be fitted with
an internal control module to give a range of control options
(which includes: timer, humidity, motion sensor, pull cord or
combinations of these functions).
These optional modules are available separately and can be
fitted at the time of installation or retrofitted (see page 15).
H
I
30
148
29
-
52
177
iCON 15
46
-
Page 3 of 16
Front cover removal
Module clip
Terminal
connector
Module fitting
place
3
1
To remove front cover assembly, first make sure the fan is off,
isolated from the power supply and the iris shutter is fully
closed.
1. Undo the locking screw at the bottom edge of the cover
using a screwdriver.
2. Rotate the cover a few degrees anticlockwise until it clicks
out from the fittings.
3. Remove the cover by pulling it out.
To refit the cover, reverse the above procedure. If when refit-
ting the front cover the iris stays open, remove the cover and
don't attempt to refit it for approx. two minutes (allowing the
actuator to retract back in the closed position). Then try again.
Page 7 of 16
Electrical installation
All electrical installation must be carried out by an approved
electrician in accordance with Approved Document Part P of
U.K. Building Regulations and to the latest IET standards, or
Current
Noise level
the appropriate regulations in the country of installation.
[A]
[dB(A) @ 3m]
The fan requires a 230V 50Hz single phase supply, class II
0.05
28.8
equipment (marked as stated in BS EN 60417). An external
0.17
33.3
3A fuse and a 30mA RCD is required for each fan unit.
0.45
41.6
The iCON 230V fan range is IPX4 rated and therefore it is
suitable for mounting in bathrooms (incl. zones 1 and 2), toi-
lets, kitchens and utility rooms, as long as it is not exposed to
water jets (i.e. can be installed above fixed shower head).
All wiring and switches for fans shall be selected and sited in
accordance with BS7671 (IET Wiring Regulations) or relevant.
Important
Do not place the ventilator near direct heat sources, e.g. radi-
ant heaters, or where temperatures can exceed 40°C (104°F).
Wiring with no control module fitted:
iCON 30 & 60
Fitting on the wall
iCON 15
2
Recessing fans in the wall
The iCON 15 requires a 110mm diameter hole through the
wall lined with a 100mm internal diameter duct.
The iCON 30 requires a 110mm diameter hole through the
wall, counter bored 160mm to a depth of 80mm. The hole
should be lined with a 100mm internal diameter duct.
The iCON 60 requires a 160mm diameter hole through the
wall, counter bored 190mm to a depth of 80mm. The hole
should be lined with a 150mm internal diameter duct.
Surface mounting fans on the wall
When surface mounting the iCON 30 and iCON 60 the sup-
plied mounting skirt should be used.
The iCON 30 requires a 110mm diameter hole through the
wall lined with a 100 mm internal diameter duct.
The iCON 60 requires a 160mm diameter hole through the
wall lined with a 150 mm internal diameter duct.
Ensure all vapour barriers are properly restored.
Page 4 of 16
iCON 30 (R)
iCON 60 (R)
Page 8 of 16

Advertisement

loading

Summary of Contents for Airflow iCON series

  • Page 1 Fan dimensions Range overview Electrical installation Airflow® iCON® 230V fans are available in three model sizes All electrical installation must be carried out by an approved and can be fitted to a wall or ceiling. electrician in accordance with Approved Document Part P of U.K.
  • Page 2 52634510B Silver For detailed standard warranty terms and conditions see © Airflow Developments Ltd. Airflow Developments Limited reserve the right, in the interests of continuous develop- our website or contact Customer Service. 52634502B Chrome ment, to alter specifications without prior notice. All orders are accepted subject to our conditions of sale which are available on request.