Siemens 6RA7086-6KS22 Operating Instructions Manual page 170

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Start-Up
Operation without tacho (EMF control)
5.3
P083 = 3:
P115
Freely wired actual value
5.4
P083 = 4:
P609
Field data
6
Field control
6.1
P082 = 0:
P082 = 1:
P082 = 2:
P082 = 3:
Field weakening
6.2
P081 = 0:
P081 = 1:
Selection of basic technological functions
7
Current limits
7.1
P171
P172
Torque limits
7.2
P180
P181
7-12
The actual speed is supplied from the "Actual EMF" channel (K0287),
but weighted with P.
EMF at maximum speed
(1.00 to 140.00% of rated converter supply voltage (r078.001)).
The actual value input is defined with P609.
Number of connector to which actual speed controller value is connected.
Internal field is not used
(e.g. with permanent-field motors)
The field is switched together with the line contactor
(field pulses are enabled/disabled when line contactor closes/opens)
Automatic connection of standstill field set via P257 after a delay parameterized via
P258, after operating status o7 or higher has been reached
Field current permanently connected
No field weakening as a function of speed or EMF
Field weakening operation as a function of internal EMF control so that, in the field
weakening range, i.e. at speeds above rated motor speed (= "threshold speed"),
the motor EMF is maintained constantly at setpoint
EMFset (K289) = P101 – P100 * P110.
Motor current limit in torque direction I (in% of P100)
Motor current limit in torque direction II (in% of P100)
Torque limit 1 in torque direction I
(in % of rated motor torque)
Torque limit 1 in torque direction II
(in % of rated motor torque)
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
6RX1700-0AD76