Event
Event display
classifi cation
0000
INFORMATION
CPL NOT SIGNED:<fi le> <cplid>
PKL VERIFICATION OK:<fi le> <pklid>
PKL VERIFICATION NG:<fi le> <pklid>
PKL NOT SIGNED:<fi le> <pklid>
DCP VALIDATION START:<dcpid>
DCP VALIDATION END :<dcpid>
DCP VALIDATION CANCELED:<dcpid>
DCP VALIDATION OK: <dcpid>
DCP VALIDATION NG: <fi le> in
<dcpid>
DCP VALIDATION NG: ASSETMAP
MISSING in <dcpid>
DCP VALIDATION NG: PKL MISSING
in <dcpid>
KDM IMPORTED:<cplid>
KDM DELETED (CPLID) :<cplid>
KDM DELETED (KDMID):<kdmid>
KDM EXPIRED: <kdmid>
SHOW START:<cplid>
SHOW END:<cplid>
ANY FILE RETRIEVED:<fi le>
ANY FILE STORED:<fi le>
ANY FILE DELETED:<fi le>
CLOCK ADJUSTMENT RANGE OVER
CLIENT DISCONNECTED
PRJ INITIALIZED
PRJ DISCONNECTED
PRJ CONNECTED
PRJ DIVORCE CABLE A
PRJ DIVORCE CABLE B
PRJ DIVORCE AUTH
PRJ CERT MISMATCH
PRJ SERIAL MISMATCH
PRJ BTTRY DFCT
PRJ AUTH FAIL
PRJ CLOCK ADJUSTMENT RANGE
OVER
LMT-300
Description
The fi le name is <fi le>. The CPL signature of
<cplid> did not exist.
The fi le name is <fi le>. PKL of <pklid> succeeded
in signature verifi cation.
The fi le name is <fi le>. PKL of <pklid> failed in
signature verifi cation.
The fi le name is <fi le>. The PKL signature of
<pklid> did not exist.
The DCP validity check of <dcpid> was started.
The DCP validity check of <dcpid> was terminated.
The DCP validity check of <dcpid> was canceled.
DCP of <dcpid> succeeded in validity verifi cation.
As the result of DCP validity verifi cation of
<dcpid>, <fi le> failed.
As the result of DCP validity verifi cation of
<dcpid>, ASSETMAP failed without existing.
As the result of DCP validity verifi cation of
<dcpid>, PLK failed without existing.
KDM of <cplid> CPL was read.
KDM of <cplid> CPL was deleted.
KDM of <kdmid> was deleted.
The KDM time limit of <kdmid> has expired.
The CPL projection of <cplid> was started.
The CPL projection of <cplid> was terminated.
The <fi le> fi le in the work area of this unit was acquired.
The <fi le> fi le of a user was written into the work
area of this unit.
The <fi le> fi le in the work area of this unit was deleted.
The allowable range of the settable time setting in
one year was exceeded.
The heartbeat from SMS cannot be received
within three minutes by this unit and the estab-
lished session is disconnected.
Preparation for communication with SRX-R320
was completed.
Communication with SRX-R320 was disconnect-
ed.
Communication with SRX-R320 was established.
Disconnected LVDS cable A was detected.
Disconnected LVDS cable B was detected.
Authentication to SRX-R320 failed.
Authentication failed because the certifi cate of
SRX-R320 did not coincide.
Authentication failed because the serial number of
SRX-R320 did not coincide.
Decrease in the battery voltage of SRX-R320 was
detected.
Authentication to SRX-R320 failed.
The allowable range of the settable time setting
for one year in SRX-R320 was exceeded.
Remedy