4 Description of the SINUMERIK 810D
4.2 Interfaces
X130
SIMODRIVE 611D-Drive bus interface and I/O extension
Connector name:
Connector type:
Maximum cable length:
Special features:
X151
Device bus interface (power supply)
Connector name:
Connector type:
X304, X305, X306
Connection for axis expansion plug-in unit
Connector name:
Connector type:
X307
Pulse interface for axis 3
Connector name:
Connector type:
X341, X342,
Measuring sockets for output of 3 analog signals. The measuring values
X351, X352
that are output are assigned in the software.
Connector name:
Connector type:
Table 4-7
X411-X416
6 x measuring system connection for indirect and direct position sensing
Connector name:
Connector type:
Signals with a gray background are not required for a direct measuring system.
4-56
Assignment of the measuring sockets X341 to X352
Measuring socket
Position on the
CCU
X351
X352
X341
X342
SINUMERIK 810D Equipment Manual Configuration CCU (PHC) – 03/2006 Edition
X130
36-pole Micro Ribbon
10 m
non-isolated (no safe isolation)
X151
34-pole ribbon cable connector, male
X304, X305, X306
20-pole ribbon cable connector, male
X307
20-pole ribbon cable connector, male
X341, X342, X351, X352
Measuring socket 2 mm
Meaning
DAC 1
DAC 2
DAC 3
Ground for all DACs
X411-X416
25-pole, D-Sub male connector
Copyright © Siemens AG 2006
Section
0– 5V
0– 5V
0 – 5V