Recovering the CMU

Figure 7-5 Reset Configuration dialog

Erasing configuration

Perform this task when the CMU is in recovery mode. The purpose of this task is to
erase all changes that have been made to the configuration of the CMU and return
it to its factory settings. This includes all changes made to the wireless, IP,
Ethernet, license key, security, fault and performance parameters.
Before starting this task, check that the Recovery Options page is displayed
7-2).
To erase the entire configuration of the CMU, proceed as follows:
Procedure 7-5 Erase entire CMU configuration in recovery mode
Select Erase Configuration. The Erase Configuration dialog is displayed
1
(Figure
2
Select OK. The Recovery Options page is redisplayed with a message
indicating that the configuration has been erased.
Select Reboot. The Reboot Confirmation dialog is displayed
3
4
Select OK. The reboot progress message is displayed. On completion, the
CMU restarts.
Reconfigure the PTP 800 to meet the operator's requirements.
5
NOTE
7-18
7-6).
When the CMU is rebooted after selecting the recovery option Erase
Configuration, the IP address remains at its default setting of
169.254.1.1 and the CMU can only be accessed via a direct network
connection from the PC to the management port.
Chapter 7 Troubleshooting
(Figure
(Figure
6-14).