Lenovo ThinkSystem SR650 Maintenance Manual page 133

2u rack server
Hide thumbs Also See for ThinkSystem SR650:
Table of Contents

Advertisement

Figure 95. 2.5-inch hot-swap drive installation
Figure 96. 3.5-inch hot-swap drive installation
Step 1.
Ensure that the drive tray handle is in the open position. Slide the drive into the drive bay until it
snaps into position.
Step 2.
Close the drive tray handle to lock the drive in place.
Step 3.
Check the drive status LED to verify that the drive is operating correctly.
• If the yellow drive status LED is lit continuously, that drive is faulty and must be replaced.
• If the green drive activity LED is flashing, the drive is being accessed.
Step 4.
Continue to install additional hot-swap drives if necessary.
After installing all hot-swap drives:
1. If you have removed the security bezel, reinstall it. See "Install the security bezel" on page 93.
.
Chapter 3
Hardware replacement procedures
125