Poe Pd-Policy Priority - HP MSR1003-8S Command Reference Manual

Msr series network management and monitoring
Hide thumbs Also See for MSR1003-8S:
Table of Contents

Advertisement

undo poe pd-description
Default
No description is available for the PD that connects to a PI.
Views
PI view
Predefined user roles
network-admin
Parameters
text: Configures a description for the PD connected to the PI, a case-sensitive string of 1 to 80 characters.
Examples
# Configure the description for the PD as IP Phone for Room 101.
<Sysname> system-view
[Sysname] interface gigabitEthernet 2/0/1
[Sysname-GigabitEthernet2/0/1] poe pd-description IP Phone For Room 101

poe pd-policy priority

Use poe pd-policy priority to enable PI power management.
Use undo poe pd-policy priority to restore the default.
Syntax
poe pd-policy priority
undo poe pd-policy priority
Default
PI power management is disabled.
Views
System view
Predefined user roles
network-admin
Usage guidelines
If PI power management is enabled, when a PSE is overloaded, the PSE allocates power to new PDs
based on the priority of their PIs. Otherwise, the PSE does not supply power to new PDs.
Examples
# Enable PI power management.
<Sysname> system-view
[Sysname] poe pd-policy priority
Related commands
poe priority
150