10 NC Start-Up with HMI Advanced
10.6 Digital and analog I/O devices
10.6.6

Configuration example

840Di (configuration) –– 840Di_ET200_ADI4
(0) UR
(0) 840Di
PLC315-2DP M/S 2AF03
2
DP Master
X2
CP 342–5
4
Fig. 10-35 Example configuration: SINUMERIK 840Di with ET200 and ADI4
10-384
R
Computational time of position controller and/or signal module
Dx
User data exchange between DP master and DP slaves
MSG
Acyclic services (e.g. DP/V1, token transfer)
RES
Reserve: "active break" until the equidistant cycle has elapsed
Set the system variables, e.g. $A_OUT[8] in the parts program or
1
synchronized action
Transmit the output signal to the signal module on
2
PROFIBUS DP
Connect the signal to the output of the module.
3
In the following configuration example the following input/outputs are available
to the NC:
ET200
– 24 digital inputs
– 16 digital outputs
ADI4
– 8 digital inputs
– 16 digital outputs
Note
S
The I/O addresses of the modules are assigned automatically by "HW Con-
fig". (Manual adjustment is possible.)
S
Each I/O address refers to an input/output byte.
PROFIBUS(2): DP master system (2)
(5) IM 153