11.1 S7-1500 Motion Control V2
Parameter
Declaration
Done
OUTPUT
Busy
OUTPUT
CommandAborted
OUTPUT
Error
OUTPUT
ErrorID
OUTPUT
242
Data type
Default value
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
WORD
16#0000
Description
7
Absolute encoder adjustment (absolute)
The current position is set to the value of
the parameter "Position".
The calculated absolute value offset is
stored retentively in the CPU.
(<TO>.StatusSensor[n].
AbsEncoderOffset)
8
Passive homing
When the homing mark is detected, the
actual value is set to the value of the "Posi-
tion" parameter.
9
Canceling passive homing
A running job for passive homing is abort-
ed.
10
Passive homing
("Position" parameter has no effect)
When the homing mark is detected, the
actual value is set to the home position
configured under "Technology object >
Configuration > Extended parameters >
Homing > Passive homing".
(<TO>.Homing.HomePosition)
TRUE
Job is completed
TRUE
The job is being executed.
TRUE
During execution the job was aborted by
another job.
TRUE
An error occurred during execution of the
job. The job is rejected. The cause of the
error can be found in the "ErrorID" parame-
ter.
Error ID (Page 386) for parameter "Error"