A 'Characteristic Curve Wizard' opens.
4. To activate the internal pull up‐resistor, check the box. The DDU 7 pull up‐
resistor is used to get a 5 V signal at the analogue channel of the DDU 7. It
allows you, to use a push‐button. The fixed value of the internal pull up‐resis‐
tor is 3,010 Ohm. If using an additional external pull up‐resistor, set up the
overall resistance.
5. Click 'Next' when done.
The second part of the 'Sensitivity/Offset Wizard' opens.