EN 38
12.

12. Hardware Repair

This section provides instructions on how to remove and replace modules from the Media-Center.
12.1.
Top Cover
12.1.1.
Top Cover Removal
WARNING: Disconnect the AC power from the MCP9350i before removing the top cover.
1.
At the rear of the chassis remove the 4 torx screws (1). See Figure 12.1-1.
2.
Slide the top cover towards the rear, until the locking tabs disengage. See Figure 12.1-2.
3.
Lift the top cover straight up and remove it from the chassis.
4.
Store the top cover in a safe place.
1
12.1.2.
Top Cover Re-Assembly
To re-assemble the top cover, do all processes described in paragraph 12.1.1 in reverse order.
Note: The torque setting required for the top cover screws (1) is 8kg-cm
Note: Check the top cover for damage after re-assembly.
MCP9350i
Hardware Repair
1
1
Figure 12.1-1
1
Figure 12.1-2