Parameterizing using the BOP20 (Basic Operator Panel 20)

4.2 Displays and using the BOP20

● p0011 BOP password input (p0013)
● p0012 BOP password confirmation (p0013)
● r0019 CO/BO: Control word, BOP
● p0977 Save all parameters
Other drive objects (e.g. SERVO, VEKTOR, INFEED, TM41 etc.)
● p0010 Commissioning parameter filter
4.2
Displays and using the BOP20
Features
● Operating display
● Changing the active drive object
● Displaying/changing parameters
● Displaying/acknowledging faults and alarms
● Controlling the drive using the BOP20
Operating display
The operating display for each drive object can be set using p0005 and p0006. Using the
operating display, you can change into the parameter display or to another drive object. The
following functions are possible:
● Changing the active drive object
● Parameter display
152
– Press key "FN" and "Arrow up" -> the drive object number at the top left flashes
– Select the required drive object using the arrow keys
– Acknowledge using the "P" key
– Press the "P" key.
– The required parameters can be selected using the arrow keys.
– Press the "FN" key -> parameter r0000 is displayed
– Press the "P" key -> changes back to the operating display
Commissioning Manual, (IH1), 07/2007 Edition, 6SL3097-2AF00-0BP7
Commissioning