Vacuum Pump; Changing Vacuum Pump Oil; Reset Of Oil Change Interval - Bosch ACS 611 Original Instructions Manual

A/c service-unit
Table of Contents

Advertisement

en
56 | ACS 611 | Maintenance
11.5

Vacuum pump

11.5.1

Changing vacuum pump oil

Attention – Risk of burns from hot
surfaces
Contact with the hot vacuum pump surface
will cause severe burns.
Allow the vacuum pump to cool down.
Wear protective gloves.
i
The vacuum pump oil must always be changed after
10 hours of operation. The prompt "
appears on the screen when the vacuum pump oil
needs changing.
i
Use the vacuum pump oil (item number
SP00100086) as specified by Bosch.
Fig. 8:
Vacuum pump
!
Do not use excessive force when securing and
removing the oil drain and oil filling screw.
i
The container for catching oil should have a capacity
of approx. 1 l.
1. Place a vessel under the drain.
2. Remove drain plug and oil fill plug from vacuum
pump.
3. Drain off all the oil.
4. Screw on drain plug finger-tight.
5. Fill in vacuum pump oil.
6. Start the vacuum phase.
7. Check the oil level (sight glass).
i
The oil level should be in the middle between the
"full" and "empty" marks.
|
S P00 D00 002
2013-04-10
11.5.2
!
Observe the ACS 611 menu prompting.
1. Call up start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
3. Enter code
4. Select "CHANGE OIL" with o u and confirm with E.
 Current runtime of vacuum pump is displayed.
5. Press <MENU> until vacuum pump runtime is set to
zero.
"
REPLACE OIL
"
Oil change interval is reset.
i
Return with <Stop>.

Reset of oil change interval

ENTER CODE 0000
5555
and confirm with E.
is displayed.