Connectable components
9.3 PP 72/48D 2/2A PN
Digital outputs
Maximum switching frequency
Resistive load
Inductive load
Lamp
● Incorrect connection causes neither high level nor destruction of the outputs.
9.3.4.5

Analog X3 inputs/outputs

Cable specification
● Connectors: 12-pin socket/plug combination
● Cable: shielded
Wiring analog inputs/outputs
NOTICE
Shield support
If the analog inputs/outputs are wired, a shielded lead must be used. The shield must be
supported.
Procedure:
1. Strip cable for analog signals.
2. Secure the stripped connection piece of the cable with the shield connection clamp.
X3 pin assignment
Table 9-47
Pin
1
2
3
4
130
U
= V
- I
× R
1)
H_typical
CC
OUT
V
: Current operating voltage
CC
I
: Output current
OUT
Maximum short-circuit current: 4 A (max. 100 μs, V
R
: Maximum internal resistance = 0.4 Ω
ON
Where demand factor is 100% (all outputs active)
2)
– max. cable length: 30 m
– max. connectable core cross-section: 0.5 mm
Pin assignment (standard)
Signal name
CO1
CI1
AI1+
AI1-
min.
-
-
-
ON
Signal type
Meaning
O
Channel 1 current output for PT100
I
Channel 1 current input for PT100
I
Channel 1 analog input +
I
Channel 1 analog input -
Standard
max.
-
100 Hz
-
2 Hz
-
11 Hz
= 24 V)
CC
2
NCU 7x0.3 PN, NCU 7x0.3B PN
Manual, 06/2014, 6FC5397-1EP40-5BA1
nominal
-
-
-