Praesideo 3.5 | Installation and User Instructions | 9 | System Configuration
42.7
Fiber interface
42.7.1 Add a fiber interface
Adding a fiber interface to the system definition is
similar to adding a power amplifier (see section 42.4.1).
Go to Configure > System definition > Fiber interface, click
the Add button and:
Note
Only PRS-FIN(S) Fiber Interfaces have to be
configured. PRS-FINNA Fiber Interfaces cannot
be configured.
•
Enter a name for the fiber interface in the Name field.
The name may consist of up to 16 characters.
•
Enter the hexadecimal serial number of the fiber
interface in the Serial number field.
figure 42. 1 4: Fiber interface definition
42.7.2 Delete a fiber interface
Deleting a fiber interface from the system definition is
similar to deleting a power amplifier (see section 42.4.2).
Go to Configure > System definition > Fiber interface, select
the fiber interface that has to be deleted and click the
Delete button.
Bosch Security Systems | 2011-02
42.8 CobraNet interface
42.8.1 Add a CobraNet interface
Adding a CobraNet interface to the system definition is
similar to adding a power amplifier (see section 42.4.1).
Go to Configure > System definition > CobraNet interface,
click the Add button and:
Enter a name for the CobraNet interface in the Name
•
field. The name may consist of up to 16 characters.
The name is also shown on the display of the
CobraNet interface.
•
Enter the hexadecimal serial number of the
CobraNet interface in the Serial number field.
figure 42. 1 5: CobraNet interface definition
42.8.2 Delete a CobraNet interface
Deleting a CobraNet interface from the system
definition is similar to deleting a power amplifier
(see section 42.4.2). Go to Configure > System definition >
Cobranet interface, select the CobraNet interface that has
to be deleted and click the Delete button.
en | 336