Status; Virtual Drive Status; Physical Drive Status - Hitachi Compute Blade 500 Series User Manual

Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

3
Mount Driver & Utility CD on any directory. In the following steps, Driver
.
& Utility CD is mounted on /media/cdrom
4
Execute the following command to perform the LSI Software RAID setting
.
script.
5
The following message appears and RAID setting with LSI Software RAID
.
is executed. Wait for command prompt.
6
Since virtual drive setting with LSI Software RAID is complete, umount
.
Driver & Utility CD and remove the CD.

Status

This section virtual drives and hard physical drives.

Virtual drive status

The following table shows virtual drive status.
State
Optimal
Degraded A physical drive fails in virtual drives of RAID 1.
Offline

Physical drive status

The following table shows physical drive status.
Online
Offline / Failed
Rebuilding
Unconfigured Good
6-56
Normal: The virtual drive fully works.
Virtual drives cannot work because multiple physical drives fails in virtual
drives with redundancy or a physical drive fails in virtual drive without
redundancy.
State
Normal
Some failure has occurred.
Disconnected from the virtual drive due to failure.
In rebuilding
Not configured into a virtual drive.
LSI Software RAID Configuration Utility for disk arrays
Hitachi Compute Blade 500 Series EFI User's Guide
Description
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents