Bosch 3H/2C Installation & Operation Manual page 10

Touch-technology thermostat
Table of Contents

Advertisement

1 0 | Bosch 3H/2C Touch-Technology Thermostat
3rd Stage Temperature Differential (1°F to 5°F) (0.5°C to 2.5°C)
Set the number of degrees between when stage 2 turns on and when
stage 3 turns on.
Press the
or
to set differential value.
Press
to advance to the next screen.
CONFIG
Figure 8
Staged Off Outputs
Select whether the outputs for heating and cooling are staged off
independently or are
satisfied simultaneously.
= Outputs off simultaneously (best for dual fuel).
Outputs staged off independently.
For 2 compressor heat pumps and multi-stage gas/oil systems, stage 3 is
staged off independently when SO is set to
Press the
or
to set.
Press
to advance to the next screen.
CONFIG
CONFIG
Figure 9
Minimum Deadband (1°F to 9°F) (1°C to 5°C)
Set the minimum separation between heat setpoint and cool setpoint
in Auto Changeover Mode.
Press the
or
to set deadband value.
Press
to advance to the next screen.
CONFIG
Figure 10
Data subject to change
Heat Source: There are six heat source settings:
Figure 11
=
.
Figure 12
Installation, Operation & Application Manual
WARNING:
Incorrect settings can damage system and/or cause
potentially dangerous conditions. Use the code described in
Configuration and Thermostat Lock.
Non-Heat Pump
Electric
CONFIG
Heat Pump
Heat Pump with
2 stage or 2 compressors
and Heat Active
Reversing Valve
CONFIG
Heat Pump with
1 compressor single stage
and Heat Active
Reversing Valve
CONFIG
08.2016 | Bosch Thermotechnology Corp.
Gas
CONFIG
Heat Pump with
2 stage or 2 compressors
and Cool Active
Reversing Valve
CONFIG
Heat Pump with
1 compressor single stage
and Cool Active
Reversing Valve
CONFIG