1 0 | Bosch 3H/2C Touch-Technology Thermostat
3rd Stage Temperature Differential (1°F to 5°F) (0.5°C to 2.5°C)
—
Set the number of degrees between when stage 2 turns on and when
stage 3 turns on.
—
Press the
or
to set differential value.
—
Press
to advance to the next screen.
CONFIG
Figure 8
Staged Off Outputs
—
Select whether the outputs for heating and cooling are staged off
independently or are
satisfied simultaneously.
—
= Outputs off simultaneously (best for dual fuel).
Outputs staged off independently.
For 2 compressor heat pumps and multi-stage gas/oil systems, stage 3 is
staged off independently when SO is set to
—
Press the
or
to set.
—
Press
to advance to the next screen.
CONFIG
CONFIG
Figure 9
Minimum Deadband (1°F to 9°F) (1°C to 5°C)
—
Set the minimum separation between heat setpoint and cool setpoint
in Auto Changeover Mode.
—
Press the
or
to set deadband value.
—
Press
to advance to the next screen.
CONFIG
Figure 10
Data subject to change
Heat Source: There are six heat source settings:
Figure 11
=
.
Figure 12
Installation, Operation & Application Manual
WARNING:
Incorrect settings can damage system and/or cause
potentially dangerous conditions. Use the code described in
Configuration and Thermostat Lock.
Non-Heat Pump
Electric
CONFIG
Heat Pump
Heat Pump with
2 stage or 2 compressors
and Heat Active
Reversing Valve
CONFIG
Heat Pump with
1 compressor single stage
and Heat Active
Reversing Valve
CONFIG
08.2016 | Bosch Thermotechnology Corp.
Gas
CONFIG
Heat Pump with
2 stage or 2 compressors
and Cool Active
Reversing Valve
CONFIG
Heat Pump with
1 compressor single stage
and Cool Active
Reversing Valve
CONFIG