Drain Pump (M8) Removal; Top Solo Valve Removal; Figure 5-32: Heater Pressure Switch And Circulation Pump; Figure 5-33: Drain Pump Removal - Miele G 600 Series Technical Information

(all us models)
Hide thumbs Also See for G 600 Series:
Table of Contents

Advertisement

Technical Information

Figure 5-32: Heater Pressure Switch and Circulation Pump

Note:
When re-installing the heater pressure switch, ensure that both tabs on the switch
are engaged in the circulation pump housing, and that the seal (Figure 5-32, Item 3)
is not pinched or kinked.
5.40

Drain Pump (M8) Removal

1. Remove as much water as possible from the sump.
2. Remove the cover plate. See Section 5.5.
3. Disconnect the pump electrical connection (Figure 5-33, Item 1).
4. Release the locking tab (Figure 5-33, Item 4).
5. Turn the drain pump 90° counterclockwise (Figure 5-33, Item 3) to release it from
its mounting.

Figure 5-33: Drain Pump Removal

5.41

Top Solo Valve Removal

1. Remove the circulation pump. See Section 5.35.
2. Disconnect the electrical connection.
68
G 600/G 800

Advertisement

Table of Contents
loading