4. Mount the switch assembly to the rack by
matching the long slots on each bracket
to a set of holes on the rack. Next, insert a
combination hex-head screw through the
slots in the bracket and the holes in the
rack. Cap the screw with a hex serrated
flange nut and tighten.
The mounting holes on the upper and lower
side braces in a rack side compartment
must be between 50.8-cm (20.0-in.) and
57.3-cm (22.6-in.) apart. If the rack has
movable side braces, refer to the rack
documentation for information about
relocating side braces if they are not already
spaced for this installation.
Installing the switch horizontally in the 1-U
rack mounting space
NOTE: The filler panel must be placed in front
of the rack when the switch is mounted in the
horizontal 1-U orientation.
First Edition, July 2015. Copyright Lenovo 2015.
First Edition, July 2015. Copyright Lenovo 2015.
LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant a General Services Administration "GSA" contract, use, reproduction, or disclosure is subject to restrictions set forth in Contract No. GS-35F-05925.
LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant a General Services Administration "GSA" contract, use, reproduction, or disclosure is subject to restrictions set forth in Contract No. GS-35F-05925.
Lenovo and the Lenovo logo are trademarks of Lenovo in the United States, other countries, or both.
Lenovo and the Lenovo logo are trademarks of Lenovo in the United States, other countries, or both.
Printed in USA
Printed in USA
Quick Installation Guide
Global Console Manager
GCM16 | GCM32
Connecting the GCM switch
5. Remove the screws on each side of the
switch.
6. Line up the small holes in the long side of
each mounting bracket.
7. With a Phillips screwdriver, fasten the
mounting brackets to the switch using two
8/32-inch x 1/2-inch pan-head screws on
each side.
8. Attach four cage nuts or clip nuts to the
rack mounting flange of the rack so that the
nut is positioned on the inside of the rack.
9. Mount the switch assembly to the rack by
matching the holes in the short side of each
mounting bracket to a set of matching holes
on the rack. Insert the combination hex-head
screws through the slots in the mounting
bracket and the holes in the mounting rail,
then into the cage nuts or clip nuts.
590-xxx-501A