Technical Specifications - Maytag MFR18 Installation Instructions Manual

Commercial washer
Hide thumbs Also See for MFR18:
Table of Contents

Advertisement

Technical Specifications
| uFma (17kg)
| UFR25(10kg)
| UFR30 (13kg)
] UFR40 (la kg)
Dimensions
and Weights
Washer dimensions
26.00x28.00x41.10"
26.00x34.00x44.90"
29.50x32.30x48.20"
33.70x35.20x51.80"
(width x depth x height)
(660x710x1045
mm)
(660x865x1140
mm)
(750x820x1225
mm)
(855x895x1315
mm)
Net weight
309 lb. (140 kg.)
408 lb. (185 kg.)
430 lb. (195 kg.)
618 lb. (280 kg.)
Package dimensions
27.60x28.70x46.50" (box) 27.60x38.98x51.38"(box) 31.90x38.19x54.92" (box) 36.80x37.60x60.24" (box)
(700x730x1180
mm)
(700x990x1305
mm)
(810x970x1395
mm)
(935x955x1530
mm)
Gross weight
320 lb. (145 kg.)
430 lb. (195 kg.)
452 lb. (205 kg.)
640 lb. (290 kg.)
Transportation
volume
21.20 cu.ft. (0.6 m3)
31.80 cu.ft. (0.9 m3)
38.85 cu.ft. (1.1 m3)
48.40 cu.ft. (1.37 m3)
Electrical
Requirements
Supply voltage (50/60 Hz)
120V
1-phase*
208-240V
1-phase
208-240V
3-phase
Supply deviations
+10%, with max 1% of the frequency
+10%, with max 1% of the frequency
Fuse/Breaker Type
Slow
(curve D)
GFCI**
Class
B
Nominal motor output
600 W
600 W
0.75 kW
1.50 kW
Current (steady speed)
5A
9A
4.5A
5A
Supply protection device
10A
10A
15A
15A
Drum RPM
Wash
48 RPM
1 48 RPM
1 45 RPM
44 RPM
Spin maximum
580 RMP
1 580 RPM
] 525 RPM
505 RPM
G-factor maximum
100
Water
Supply
Requirements
Average water usage
17 gal (65 I)
124 gal (90 I)
1 30 gal (115 I)
43 gal (160 I)
Average hot water usage
4 gal (15 I)
1 6 gal (23 I)
J 8 gal (30 I)
11 gal (42 I)
Allowable water pressure
14.5-116
psi
(100-800 KPa)
Recommended
pressure
43-73 psi
(300-500 KPa)
Water inlet
BSP
3/4"
Maximum water temperature
194°F
(90°C)
Drain
System
Type
Gravity Feed
Drain diameter
3" (76 mm)
Flow rate
38.3 GPM
(145 I/min.)
Liquid Soap
Liquid soap signals
8 for PN Models/3 for PD Models (see electrical schematic)
Soap dispenser
3 compartments:
prewash, wash, and last rinse
Environmental
Requirements
Operating temperature
33.8 to 95 °F (1 to 35°C)
Relative humidity
10 to 95 %
without condensation
Elevation above sea level
Up to 3280 ft.
(1,000 m)
Storage temperature
-13 to 131°F
(-25 to 55°C)
Floor Requirements
Maximum static load
370 lb. (1.7 kN)
474 lb. (12.1 kN)
577 lb. (2.6 kN)
675 lb. (3.1 kN)
Maximum dynamic load
801 lb. (3.6 kN)
1020 lb. (4.5 kN)
1450 lb. (6.5 kN)
1994 lb. (8.9 kN)
Dynamic frequency
9.67 Hz
9.67 Hz
8.75 Hz
8.42 Hz
Noise
Noise output
1 66 dB(A)
1 66 dB(A)
J 66 dB(A)
166 dB(A)
* 2 phases of a 3-phase power supply may be used. See "Electrical Requirements".
** Consult an electrician to ensure proper GFCI connection.