Enabling Management Through External Ports - Lenovo Flex System EN2092 User Manual

1gb ethernet scalable switch
Hide thumbs Also See for Flex System EN2092:
Table of Contents

Advertisement

If necessary, obtain the IP address of the management module from your
system administrator. The management-module window opens.
Note: The User ID and Password fields are case-sensitive. Type your
information in uppercase letters only. To maintain system security,
change your password after you log on for the first time. The default
User ID is USERID, and the default password is PASSW0RD (where the sixth
character is the number zero, not the letter O).
2. From the I/O Module Tasks menu, click Configuration.
3. In the I/O Module Configuration area, click the bay number that corresponds
to the location of the switch that you installed.
4. In the IP address field in the New Static IP Configuration area, type the new
TCP/IP address of the switch; then, click Save.
Note: The management module does not check for invalid IP addresses.
5. Click Advanced Configuration. You can now start a Web session or a Telnet
session.
The Web interface and the Telnet program provide different ways to access the
same internal-switching firmware and configure it.
v If your system application requires that you use the Web interface program, see
"Configuring the switch through the switch browser-based interface" on page 21
for additional information.
v If your system application requires that you use the Telnet program, see
"Configuring the switch through the Telnet interface" on page 20 for additional
information.

Enabling management through external ports

To access and manage the switch through external interfaces, you must enable the
external ports and the ability to manage the switch through them. Use the
information in the following table to configure your ports.
External management
Disabled
Disabled
Enabled
Enabled
External ports
Disabled
Enabled
Disabled
Enabled
Description
The switch must be managed
through the management
module. No traffic is allowed on
external ports.
The switch must be managed
through the management
module. Data traffic is allowed
on external ports.
The switch can be managed
through the management
module or a blade server. No
traffic is allowed on external
ports.
The switch can be managed
through the management
module, a blade server, or a
management station that is
connected through an external
port. Data traffic is allowed on
external ports.
Chapter 2. Installing the switch