Selecting The Drop Frame Mode (Df/Ndf); Selecting The Content Of The Second Time Code Display; Area (Tc2 Sel); Selecting Ctl Display Mode (Tape Timer) - Sony SRW-5100 Operation Manual

Hd digital videoscassette player
Hide thumbs Also See for SRW-5100:
Table of Contents

Advertisement

4-3-3 Selecting the Drop Frame
Mode (DF/NDF)
Press the [F9] (DF/NDF) button to select the running mode
for the time code after frame conversion and the CTL
counter.
1)
DF: Drop frame mode
(DF is displayed.)
NDF: Non-drop frame mode
auto: The unit switches to drop frame mode when the field
frequency is 29.97 Hz or 59.94 Hz, and switches to
non-drop frame mode when the field frequency is 30
Hz or 60 Hz.
1) Drop frame mode
In order to compensate for differences between time code values from the
time code generator and the actual time that occurs when the frame
frequency of this unit is 29.97 Hz, the drop frame mode causes the time
code generator to omit the first two frames (frame 00 and 01) in each
minute except the tenth.
2) Non-drop frame mode
In this mode, drop frame mode processing is not performed. Since there is
no frame cutting, a discrepancy of about 86 seconds occurs each day in the
case of a frame frequency of 29.97 Hz.
Note
This setting is only active when the frame frequency of the
unit is 29.97 Hz, 59.94 Hz, 30 Hz, or 60 Hz.
4-3-4 Selecting the Content of the
Second Time Code Display Area
(TC2 SEL)
Select the content of the second time code display area
using the [F10] (TC2 SEL) button.
Setting Time data displayed
OFF
No display
LTC
LTC value read from the time code reader
auto
When the playback speed is within the range ±1/2
normal speed, then VITC, and if outside this
range then the LTC is displayed.
VITC
VITC value read from the time code reader
CTL
CTL signal count value
UBR
User bits read by the time code reader (LTC)
UBV
User bit value read from the time code reader
(VITC)
When a warning or similar is shown, the second time code
display area does not appear.
For details about the warnings, see "Warning Messages"
on page 105.
2)
(NDF is displayed.)
4-3-5 Selecting CTL Display Mode
(TAPE TIMER)
Press the ALT/[F1] (TAPE TIMER) buttons to select a 12-
hour or 24-hour clock for the CTL display.
+ –12H: 12-hour clock
24H: 24-hour clock
4-3-6 Presetting Pulldown Time
Code (PDPSET MENU)

(when HKSR-5001 is installed)

To preset the pulldown time code when this unit is
operated in 23.98PsF/24PsF mode, use the following
procedure.
1
Press the TC button, then press the ALT button.
2
Press the [F2] (PDPSET MENU) button.
The PDPSET menu appears.
3
Press the [F1] (PRESET MODE) button to select 24F
or 30F time code to be preset.
The selected time code is framed with the thick line.
Each press of the button switches time code between
24F and 30F.
24F: Presets the 24 frames time code. The A frame of
the pulldown sequence is preset.
55
4-3 TC Menu

Advertisement

Table of Contents
loading