Summary of Contents for Pioneer 500 ST

  • Page 2: Table Of Contents

    Manual Operation of Door.........................16 Operating Instructions ........................16 Adjustment of Brake...........................17 Emergency Egress............................18 Door Panel Adjustments ..........................20 500 ST Door Wiring Diagram ........................21 Pioneer Smart Controller Wiring Diagram ....................22 Please Retain This Manual for Future Reference Part No. 4801-5154 Rev 4-08 Table of Contents...
  • Page 4: Warnings (Avertissements)

    Equipment And The Hazards Involved Should Install, Adjust, And/Or Service This Equipment. Read And Understand This Manual In Its Entirety Before Proceeding. Failure To Observe This Precaution Could Result In Severe Bodily Injury Or Death! Part No. 4801-5154 Rev 4-08 500 ST Door Page 4 of 25...
  • Page 5: Important Installation Instructions

    Manufacturer’s Owner’s Manual. An improperly operating or balanced door can cause severe injury or death. Have trained door systems technician make repairs to cables, spring assemblies, and other hardware. SAVE THESE INSTRUCTIONS. Part No. 4801-5154 Rev 4-08 500 ST Door Page 5 of 25...
  • Page 6 équipement et les hasards ont enveloppé devoir installer, arranger, et/ou - la révision cet équipement. R|ead| et comprendre ce manuel en entier avant que procéder. F|ailure| à observer cette précaution peut résulter dans dommage corporel sévère ou mort ! Part No. 4801-5154 Rev 4-08 500 ST Door Page 6 of 25...
  • Page 7 Formez les technicien de systèmes de porte faitez les réparations per les câbles, réunions de source, et autre quincaillerie. SAUVEZ CES INSTRUCTIONS Part No. 4801-5154 Rev 4-08 500 ST Door Page 7 of 25...
  • Page 8: Limited Warranty

    This warranty gives you specific legal rights and you may also have other rights that vary from area to area. Warrantor: Pioneer PO Box 338 740 Beechcroft Rd. Spring Hill, Tennessee 37174 Phone 866-753-2655 Part No. 4801-5154 Rev 4-08 500 ST Door Page 8 of 25...
  • Page 12: Assembly Of Parts

    Left vertical member Placement of Parts for Assembly Lay left track, right track, and horizontal member face down in front of the clear opening as shown. Horizontal member Part No. 4801-5154 Rev 4-08 500 ST Door Page 12 of 25...
  • Page 13: Infrared Sensor Connectors

    Door can be set to stop if beams are broken while closing or to stop and reverse to the full open position. Refer to the Pioneer SC-325 Controller Manual for more information.
  • Page 14 On the lower and upper flanges of the assembly to the clear opening. horizontal member there are attachment points for fastening screws. Fasten Tek screws (in steel) or lag screws (in wood) Part No. 4801-5154 Rev 4-08 500 ST Door Page 14 of 25...
  • Page 15: Connecting The Electrical Power

    Operation of Door 2. Depress manual control button. Door curtain will roll up to 'open' position. Refer to the Pioneer SC-325 Controller Manual Depress button to open or close door as desired. for initial setup. After wiring the controller to...
  • Page 16: Manual Operation Of Door

    Manual Operation of Door Operating Instructions The 500 ST door can be operated manually in the event of a power outage or if there is a motor malfunction. To operate the door manually, perform the following instructions. Warning! Disconnect All Electrical Power To Motor Before Attempting...
  • Page 17: Adjustment Of Brake

    9. Replace cover (B). 5. Remove cover (B). 10. Replace four Phillips screws (A). 6. Straighten the bent tab (C) of spider nut. 11. Disengage brake lever (D). 12. Adjustment complete. Part No. 4801-5154 Rev 4-08 500 ST Door Page 17 of 25...
  • Page 18: Emergency Egress

    Next pull down on the strap until the door stops. See Step 2. This will allow the doors to open enough for a person to exit the structure. Pull strap downward until door stops. Pull strap away from retainers to center of door. Part No. 4801-5154 Rev 4-08 500 ST Door Page 18 of 25...
  • Page 19 RESETTING (CLOSING) THE DOOR After the 500 ST door is opened by using the Emergency Egress Strap, the door must be carefully re-set to ensure proper operation in the future. First, firmly hold strap, then press the Cam Buckle Release. See Closing Step 1 below.
  • Page 20: Door Panel Adjustments

    Tension Raise or lower Pipe panel material Outside Front bar Tension Pipe Inside panel Center panel (Shown relaxed) Outside panel Clearance of 1/4"-1/2" (6.35mm -12.7mm) between tension pipes Part No. 4801-5154 Rev 4-08 500 ST Door Page 20 of 25...
  • Page 21: St Door Wiring Diagram

    12. 500 ST Door Wiring Diagram See page 19 See page 19 WARNING! Head Unit Must Be Properly Grounded. Part No. 4801-5154 Rev 4-08 500 ST Door Page 21 of 25...
  • Page 22: Pioneer Smart Controller Wiring Diagram

    13. Pioneer Smart Controller Wiring Diagram See page 18 See page 18 Part No. 4801-5154 Rev 4-08 500 ST Door Page 22 of 25...
  • Page 23 Part No. 4801-5154 Rev 4-08 500 ST Door Page 23 of 25...
  • Page 24 Part No. 4801-5154 Rev 4-08 500 ST Door Page 24 of 25...
  • Page 25 NOTES:...