Installation distances and measurements (mm)

If a hood is installed above the hob, read the instructions for fitting the hood where it indicates the correct
distances to be complied with.

Injectors table

Category II2L3B/P
Type of gas used
NATURAL GAS
(Methane)
G25
semi-rapid
LIQUID
PETROLEUM GAS
(Butane) G30
semi-rapid
(Propane) G31
Type of gas used
G25 25 mbar
G30/G31 30 mbar
Electric Power: 230 V ~ 50 Hz
Type of
Injector
burner
marking
wok 3C
151
rapid
132
100
auxiliary
79
wok 3C
102
rapid
87
67
auxiliary
50
Configuration
model
3C - R - SR - SR - AUX
3C - R - SR - SR - AUX
Nominal heat
Nominal
flow kW
consumption
4,00
443 l/h
3,00
332 l/h
1,65
183 l/h
1,00
111 l/h
4,00
291 g/h
3,00
218 g/h
1,65
120 g/h
1,00
73 g/h
Nominal heat
flow kW
11,30
11,30
7
Reduced heat
flow kW
min.
1,55
0,60
20
0,35
0,35
1,55
0,60
25
0,35
0,35
Overall nominal
Required air (m
consumption
for the combustion 1 m
1252 l/h
822 g/h
Gas presssure
(mbar)
nom.
max
25
30
30
35
3
)
3
of gas
8,187
30,94