Dcs Manual Test Mode - Motorola 880 Service Manual

Gsm/dcs dualband
Table of Contents

Advertisement

DCS Manual Test Mode

Introduction
The phones are equipped with a Manual
Test Mode capability. This capability allows
service personnel to take control of the tele-
phone, and by entering certain keypad
sequences, make the telephone perform
desired functions. To enter the manual-test
mode, a Test SIM card (Part No 8102430Z01)
is required.
Test SIM Card Insertion/removal
The Test SIM card must be inserted into the
unit correctly to access Manual Test Mode.
The whole SIM card should slide completely
and securely into the slot at the base of the
phone. Ensure that the contacts of the card
face towards the front of the phone i.e.
towards the flip. See "SIM Card Insertion/
Removal" on page 12.
The sliding, card release button will move
upwards as the SIM card is inserted. When
the button reaches the top of its recess and
the card is flush with the base of the phone,
it is inserted correctly. To remove the SIM
card from the unit, push the sliding SIM
card release button downwards.
The card will then be pushed out far enough
to allow complete removal. The User Guide
contains full information about inserting
and removing the SIM card.
12/9/97
Accessing The Manual Test Mode
When the Test SIM card is in place, power
up the telephone. Once the initial automatic
'wake up' sequence has taken place
correctly, depress the # key (on the units
keypad) for three seconds. After three
seconds 'TEST' should appear in the display,
indicating that the unit is now in the Manual
Test Mode. Table 6: "DCS Test Commands"
on page 19 shows the available Manual Test
commands
results.If a customer should forget the secu-
rity code in their unit, it can only be read or
changed by using a Test SIM card.
Table 6: DCS Test Commands
Key
Sequence
#(hold
down for 2
sec.)
01#
02xxyyy#
03x#
05x#
07x#
08#
09#
10#
11xxx#
12xx#
13x#
14x#
15x#
16#
19#
20#
22#
68P09403A50
Testing
and
their
corresponding
Test Function/Name
Enter manual test mode
Exit Manual Test Mode
Display/modify TX power level
DAC & load PA calibration table
DAI
Initiate Exec Error Handler Test
Mute RX audio path
Unmute RX audio path
Mute TX audio path
Unmute TX audio path
Program main LO to channel
Set TX power level to fixed
value
Display memory block usage
Initiate Out of Memory condi-
tion
Generate tone
Mute tone generator
Display S/W version number
of Call Processor
Display S/W version number
of Modem
Display S/W version number
of Speech Coder