INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: ANSI Z21.50 ● CSA 2.22 FOR VENTED GAS APPLIANCES.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS ANSI Z21.50 CSA 2.22 FOR VENTED GAS FIREPLACES
LHD62N

NATURAL GAS

LHD62P
PROPANE
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

SAFETY INFORMATION

WARNING
!
If the information in these instructions are
not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier from
a neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier,
call the fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certifi ed kit is used.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
$10.00
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
WARNING
!
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
C E R T I F I E D
1.37
W415-1068 / A / 10.17.12
1

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon LHD62N

  • Page 1: Natural Gas

    Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com $10.00...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE / LIGHTING INSTRUCTION LOCATION SHIPPING HANDLES VENTING VENTING LENGTHS AND COMPONENTS FOR DIRECT VENT INSTALLATIONS TYPICAL VENT INSTALLATIONS MINIMUM AIR TERMINAL LOCATION CLEARANCES VENT APPLICATION FLOW CHART DEFINITIONS ELBOW VENT LENGTH VALUES HORIZONTAL TERMINATION...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW See the section See the section “VENTING - VENTING “FRAMING - See the section LENGTHS AND AIR TERMINAL MINIMUM “FRAMING” LOCATIONS” MANTEL CLEARANCES” See the section “FRAMING - MINIMUM CLEAR- ANCE TO See the section COMBUSTIBLE “FRAMING - ENCLOSURES”...
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi...
  • Page 5: Dimensions

    DIMENSIONS ELECTRICAL INLET INLET Ø 10 Ø 8 W415-1068 / A / 10.17.12...
  • Page 6: General Instructions

    GENERAL INSTRUCTIONS WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPENED OR REMOVED. PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE. PROVIDE ADEQUATE VENTILATION. NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48”...
  • Page 7: General Information

    GENERAL INFORMATION FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! LHD62 Altitude (FT) 0-4500 0-4500 Max. Input (BTU/HR) 50,000 50,000 Min. Input (BTU/HR) 37,000 40,000 Min. Inlet Gas Supply Pressure* Max. Inlet Gas Supply Pressure* Manifold Pressure* * Measure under fl...
  • Page 8: Rating Plate / Lighting Instruction Location

    WOLF STEEL LTD. SERIAL NUMBER/ NO. DE SÉRIE: LHD62 24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA W385-1864 INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to the model, venting and gas type of the appliance.
  • Page 9: Shipping Handles

    SHIPPING HANDLES IMPORTANT This appliance fully dressed weighs 575lbs. Shipping brackets were shipped secured to the appliance. The unit can be lifted by inserting the shipping handle through a set of holes. Shipping brackets must eventually be removed if framing to minimum enclosure dimensions.
  • Page 10: Venting Lengths And Components For Direct Vent Installations

    VENTING LENGTHS AND COMPONENTS FOR DIRECT VENT INSTALLATIONS For vent systems that provide seals on the inner exhaust fl ue, only the outer air intake joints must be sealed using a red high temperature silicone (RTV). This same sealant may be used on both the inner exhaust and outer intake vent pipe joints of all other approved vent systems except for the exhaust vent pipe connection to the fi...
  • Page 11: Typical Vent Installations

    TYPICAL VENT INSTALLATIONS 16” MINIMUM 20” 40 FEET MAXIMUM MAXIMUM 3 FEET MINIMUM 48” MINIMUM 84” MINIMUM PLUS 36” RISE* 36” * See “VENTING” section. W415-1068 / A / 10.17.12...
  • Page 12: Minimum Air Terminal Location Clearances

    MINIMUM AIR TERMINAL LOCATION CLEARANCES COVERED BALCONY APPLICATIONS = 3 feet = 2 x ACTUAL feet INSTALLATIONS CANADA U.S.A. 12” 12” Clearance above grade, veranda porch, deck or balcony. 12” 9” Clearance to windows or doors that open. Δ Δ 12”...
  • Page 13: Vent Application Flow Chart

    VENT APPLICATION FLOW CHART TOP EXIT Horizontal Termination Vertical Termination Vertical rise is equal Vertical rise is equal Vertical rise is less Vertical rise is less to or greater than to or greater than than horizontal run than horizontal run the horizontal run the horizontal run Horizontal run +...
  • Page 14: Horizontal Termination

    HORIZONTAL TERMINATION ) < (V See graph to determine the required vertical Simple venting confi guration (only one 90° elbow) rise V for the required horizontal run H REQUIRED VERTICAL RISE IN FEET V 12.5 17.5 HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H...
  • Page 15 ) > (V Simple venting configuration (only one 90° elbow) See graph to determine the required vertical rise V for the required horizontal run H 147” REQUIRED VERTICAL RISE IN INCHES V 57” 48” 2’ 12.5’ 19.5’ HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and V...
  • Page 16: Vertical Termination

    VERTICAL TERMINATION ) < (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H REQUIRED VERTICAL RISE IN FEET V HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and V For vent configurations requiring one or more 90°...
  • Page 17 ) > (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H REQUIRED VERTICAL RISE IN FEET V HORIZONTAL VENT RUN PLUS OFFSET IN FEET H The shaded area within the lines represents acceptable values for H and V For vent configurations requiring more than two 90°...
  • Page 18: Installation

    4.0 INSTALLATION WARNING FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS EXACTLY. ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING EITHER RED RTV HIGH TEMP SILICONE SEALANT W573-0002 (NOT SUPPLIED) OR BLACK HIGH TEMP MILL PAC W573-0007 (NOT SUPPLIED) WITH THE EXCEPTION OF THE APPLIANCE EXHAUST FLUE COLLAR WHICH MUST BE SEALED USING MILL PAC.
  • Page 19: Horizontal Installation

    4.1.1 HORIZONTAL INSTALLATION WARNING THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE. This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal location, cut and frame a hole in the exterior wall as illustrated to accommodate the fi...
  • Page 20: Using Flexible Vent Components

    USING FLEXIBLE VENT COMPONENTS WARNING DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND ELBOWS. KEEP IT PULLED TIGHT. SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER FLEX PIPE.
  • Page 21: Vertical Air Terminal Installation

    4.2.2 VERTICAL AIR TERMINAL INSTALLATION WARNING MAINTAIN A MINIMUM 2” SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 22: Appliance Vent Connection

    4.2.3 APPLIANCE VENT CONNECTION Install the inner fl ex pipe to the appliance. Secure with 6 screws #8 X 1/2” and fl at washers. Seal the joint and screw holes using the high temperature sealant W573-0007 (not supplied). SELF DRILLING Install the outer fl...
  • Page 23: Gas Installation

    GAS INSTALLATION WARNING RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 24: Framing

    5.0 FRAMING WARNING RISK OF FIRE! IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE APPLIANCE ENCLOSURE BE “FINISHED” (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH ANY OTHER OUTSIDE WALL OF A HOME.
  • Page 25 WARNING EDGES ARE SHARP, ALWAYS WEAR GLOVES WHEN WORKING WITH SHEET METAL. Erect the steel frame supplied as illustrated. Attach the metal studs (5) to the appliance as illustrated and secure with 2 screws each. Set the header onto the studs as illustrated and secure with 2 screws each. NOTE: For heavier fi...
  • Page 26 * When constructing the enclosure allow for fi nishing material thickness to maintain clearances. IMPORTANT: Before fi nishing in the appliance test the operation using the remote control, cycling it through all of its different modes, see “OPERATION” section. Should trouble shooting be required, access to the controls can be made through the pre-fi...
  • Page 27: Minimum Clearance To Combustible Enclosures

    MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES WARNING THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS SUCH AS BRICK, MARBLE, GRANITE, ETC., AS LONG AS THESE MATERIALS NEVER OVERHANG INTO THE APPLIANCE OPENING. IMPORTANT: The LHD62 requires a minimum inside enclosure height of 96”, measured from the bottom of the appliance.
  • Page 28 NON-COMBUSTIBLE TOP OF ENCLOSURE COMBUSTIBLE (COMBUSTIBLE) 0” IF NON- STEEL COMBUSTIBLE STUD MINIMUM 7” FINISHING IS FRAME USED SUCH AS 3” BRICK AND STONE. 2” NON-COMBUSTIBLE FIRESTOP ASSEMBLY 68” MINIMUM 96” MINIMUM ENCLOSURE 84” HEIGHT MINIMUM PLUS RISE ** TOP OF 28”...
  • Page 29: Installing Cement Board

    INSTALLING CEMENT BOARD WARNING A NON-COMBUSTIBLE FINISHING MATERIAL BORDER, SUCH AS BRICK, MARBLE, GRANITE, ETC. IS REQUIRED. FINISHING WITH JUST CEMENT BOARD TO THE SIDES AND TOP OF THE APPLIANCE IS NOT ALLOWED. THE SURFACE ABOVE THE APPLIANCE GETS VERY HOT. IF PROPER FINISHING MATERIALS ARE NOT USED, CRACKING CAN OCCUR.
  • Page 30: Non-Combustible Finish Material

    NON-COMBUSTIBLE FINISH MATERIAL WARNING: Non-combustible fi nishing material tight to the frame around the operating door must not project more than 1” from the face of the door (all four sides). If greater projections are needed, increase the clearance to the sides and top by 2” for every 1” projection. If using LPS62 surround , then 2”...
  • Page 31: Minimum Combustible Mantel Clearances

    MINIMUM COMBUSTIBLE MANTEL CLEARANCES WARNING RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE CLEARLY MAINTAINED.
  • Page 32: Finishing

    6.0 FINISHING WARNING RISK OF FIRE! NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED. DO NOT STRIKE, SLAM OR SCRATCH GLASS.
  • Page 33: Trim Installation

    NOTE: It is recommended to perform this task with two people There are 8 spring latches securing the main glass door, 4 of those latches are across the top and 4 along the bottom. To access these latches, the 4 piece door trim must be removed.
  • Page 34: Glass Media Installation

    GLASS MEDIA INSTALLATION WARNING CLEAN THE GLASS MEDIA PRIOR TO INSTALLATION. BEFORE APPLYING THE CLEANED GLASS, ENSURE THAT IT IS DRY. DO NOT CHANGE OR SUBSTITUTE THE GLASS MEDIA MATERIAL PROVIDED WITH THIS APPLIANCE. IF REPLACING, USE ONLY THE REPLACEMENT GLASS MEDIA AVAILABLE FROM YOUR AUTHORIZED DEALER / DISTRIBUTOR.
  • Page 35: Logo Placement

    LOGO PLACEMENT LOGO 7.0 ELECTRICAL CONNECTION WARNING DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED SERVICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE ELECTRICAL CIRCUIT. RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE APPLIANCE WALL SWITCH.
  • Page 36: Receptacle Wiring Diagram

    RECEPTACLE WIRING DIAGRAM PLASTIC BUSHING PRE-FINISHING ACCESS PANEL ELECTRICAL COVER CABLE CONNECTOR BATTERY HOLDER INSTALLATION Battery holder must be located within 8 feet of this side of the appliance and must be accessible for programming the remote. Install the battery holder into a standard electrical switch box.
  • Page 37: Schematic

    SCHEMATIC WARNING DO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH. NIGHT BLOWER LIGHT W415-1068 / A / 10.17.12...
  • Page 38: Operation

    8.0 OPERATION GENERAL TRANSMITTER LAYOUT Key Lock Low Battery Alarm Low battery alarm Transmission Room Temperature CPI mode Flame ON Night Light Blower (NOT AVAILABLE WITH THIS MODEL) INITIALIZING THE TRANSMITTER/BATTERY HOLDER FOR THE FIRST TIME Install the 4 AA batteries into the Profl ame 2 battery holder, note the polarity of the batteries and insert as indicated on the cover (+/-).
  • Page 39: Temperature Display

    TEMPERATURE DISPLAY With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same °F °C time to change from degrees F to C. Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of the Room Temperature display.
  • Page 40: Continuous Pilot / Intermittent Pilot (Cpi / Ipi) Selection

    CONTINUOUS PILOT / INTERMITTENT PILOT (CPI / IPI) SELECTION Use the Mode Key to guide you to the CPI mode °F °F icon. Transmitter in the OFF position. Press the UP/DOWN to switch between IPI and CPI modes. A single BEEP will confi rm reception of the command.
  • Page 41: Operating Instructions

    9.0 OPERATING INSTRUCTIONS WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 42: Adjustment

    10.0 ADJUSTMENT 10.1 RESTRICTING VERTICAL VENTS Vertical installations may display a very active fl ame. If this appearance is not desirable, the vent exit must be restricted using a restrictor vent kit. Refer to “ACCESORIES” in the “REPLACEMENTS” section for the appropriate kit.
  • Page 43: Venturi Adjustment

    E - F I N I I N G Before fi nishing in the appliance test the operation using the remote control, cycling it through all of its different modes, see “OPERATION” section. Once fi nished in, access to the control components can only be done through the inside of the appliance.
  • Page 44: Maintenance

    11.0 MAINTENANCE MAINTENANCE MAINTENANCE WARNING MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
  • Page 45: Control Access

    11.2 CONTROL ACCESS Once the appliance has been framed and fi nished, control access can only be achieved by removing the access panel inside the fi rebox at the right end. The following sub sections take you through the steps of accessing the control as if the appliance is installed.
  • Page 46: Burner Removal

    11.4 BURNER REMOVAL *Prior to removing the burner follow the “DOOR REMOVAL” proccess and then follow the media removal instructions located under the “MAINTENANCE” section. Remove the media tray by removing all screws securing the front, rear and side panels. Remove the 8 screws that secure the burner/mesh to the appliance.
  • Page 47: Night Light Replacement

    11.6 NIGHT LIGHT REPLACEMENT Your appliance came equipped with our “NIGHT LIGHT”. The light has been pre- wired and can be controlled by remote control. SCREWS It is recommended that the NIGHT LIGHT be in the off position when the appliance is on.
  • Page 48: Glass / Door Replacement

    11.9 GLASS / DOOR REPLACEMENT WARNING DO NOT USE SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
  • Page 49: Replacements

    DESCRIPTION W010-2829 DOOR LATCH ASSEMBLY W010-2883 FIRESTOP SPACER ASSEMBLY W010-2581 MAIN DOOR ASSEMBLY (C/W GLASS AND GASKET) W225-0311 MAIN DOOR (FRAME ONLY) W385-0334 NAPOLEON® LOGO W190-0048 RECEIVER/IFC IGNITION BOARD W660-0126 REMOTE TRANSMITTER W750-0220 WIRE HARNESS GTMFS W010-2885 TOOL, LATCH W750-0214 WIRE, 12”...
  • Page 50 CONTROL COMPONENTS REF NO. PART NO. DESCRIPTION W175-0227 CONNECTOR 3/8 FLEX W445-0021 CONNECTOR 3/8 TUBE TO 3/8 PIPE W725-0046 GAS VALVE W725-0056 NG VALVE - S.I.T. (ELEC.) W725-0057 LP VALVE (ELEC.) W190-0048 IPI IGNITION CONTROL BOARD W240-0010 ELECTRODE BULKHEAD W255-0021 PILOT TUBE BULKHEAD, FITTING W707-0006 TRANSFORMER...
  • Page 51 ACCESSORIES REF NO. PART NO. DESCRIPTION W573-0007 HI-TEMP SEALANT GD-501 HEAT GUARD W175-0249 10” COUPLER W175-0002 8” COUPLER W585-0092 VENT PIPE SHIELD MKGK GLASS EMBERS - BLACK MKGB GLASS EMBERS - BLUE MKGR GLASS EMBERS - RED MKGA GLASS EMBERS - AMBER MEGK BLACK GLASS EMBERS MEKT...
  • Page 52: Troubleshooting

    13.0 TROUBLESHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 53 SYMPTOM PROBLEM TEST SOLUTION Exhaust fumes Appliance is spilling. Check door seal. smelled in room, Check for exhaust damage. headaches. Check that venting is installed correctly. Room is in negative pressure; increase fresh air supply. Pilot will not light. Wiring. Verify the wire for the sensor and the wire for the ignitor Makes noise with are connected to the correct terminals (not reverse) on...
  • Page 54 SYMPTOM PROBLEM TEST SOLUTION Pilot sparks but Gas supply. Verify that the incoming gas line ball valve is “Open”. will not light. Verify that the inlet pressure reading is within acceptable limits, inlet pressures must not exceed 14” W.C. Module is not grounded. Verify the value and pilot assemblies are properly grounded to the metal chassis of the fi...
  • Page 55: Warranty

    All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim. During the fi rst 10 years NAPOLEON® will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge. From 10 years to life, NAPOLEON®...
  • Page 56 W415-1068 / A / 10.17.12...