POST error codes

The following table describes the POST error codes and suggested actions to
correct the detected problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, ThinkServer TS100 Machine Types 6431, 6432, 6433, and 6434," on page 37
to determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
062
Three consecutive boot failures using the
default configuration.
101
Tick timer internal interrupt failure.
102
Internal timer channel 2 test failure.
106
Diskette controller error.
151
Real-time clock error.
Action
1. Update the system firmware to the latest level
(see "Updating the firmware" on page 17).
2. (Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the system
board.
(Trained service technician only) Replace the system
board.
1. Make sure that the Configuration/Setup Utility
program correctly reflects the diskette drive
information.
2. Reseat the diskette drive cable.
3. Reseat the diskette drive.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Diskette drive cable
b. Diskette drive
c. (Trained service technician only) System
board
1. Reseat the battery.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) System
board
135