9.6.4 Recording Power Sweep Mode for
Recording Power Calibration
9.6.4.1 Sweep recording on CD-R
• Sweep recording of ±2 steps of the reference power is made three
times.
1 frame
Reference power
+1
–1
–2
15 frames
Recording Power Sweep
9.6.4.2 Sweep recording on a CD-RW
• Sweep recording of -1 mW to +3 mW of the reference power is
made three times.
1 frame
Reference power
+2mW
+1mW
–1mW
Recording Power Sweep
9.6.5 Playback RF Estimating Mode for
Recording Power Calibration
The PCA TEST area recorded in Recording Power Sweep mode is
played back to check the RF waveform and find the optimum
recording power.
PDR-555RW, PDR-V500, PDR-19RW, PDR-509
+2
+3mW
15 frames
10. ABOUT TEST MODE
OPERATIONS
Test mode is provided to permit you to easily achieve adjustments
and confirmation required for servicing.
When you set the unit to Test mode, the front-panel keys have
different functions from these in Normal mode. By operating these
keys in the specified sequence, you can perform the required
adjustments and confirmations.
Relationship between Test mode and Normal mode
Normal mode
Playback
Recording
Finalizing
• • • • •
Test mode
Mechanism servo control for adjustments
[Setting the unit to Test mode]
You can set the unit to Test mode with the following procedure:
1. Turn off the power.
2. Short-circuit the pattern for Test mode.
3. Turn on the power.
(When the unit enters Test mode, RAM information of the
mechanism control is cleared.)
If Test mode is set correctly, displays different from those in ordinary
power-up state are obtained. (All the FL indicators light, and REC
LED lights in amber. (For PDR-509, REC LED lights in red. ) )
If the displays are the same as those in the normal mode, Test mode
may not have been set correctly. Repeat steps 1 to 3 above.
Caution: Before setting the unit to Test mode, be sure to set the
INPUT selector to ANALOG.
If the selector is not set to ANALOG, malfunctions may
occur in Adjustment mode.
[Releasing Test mode]
You can release Test mode with the following procedure:
1. Press the STOP key to stop all operations.
2. Turn off the power.