Positional deviation measurement
[2] Setting details
An explanation of item 4 MEAS. PROG. COND (conditions for measurement programs) from the
TYPE00-MEAS0 (object type - measurement 0) menu.
On the MAIN OPS MENU item, move the cursor to SET-SCRN item, and press the SET key.
-On the [SYSTEM SETUP] menu, move the cursor to 2 OBJECT TYPE COND and press the SET key.
-Select item 4 MEAS.0, CAMERA 1 (measurement 0, camera 1), or 6 MEAS.0, CAMERA 2
(measurement 0, camera 2), on the [OBJECT TYPE COND] (conditions for object types) menu.
Select item 4MEAS. PROG. COND (conditions for measurement program)
9
When you specify a 1P-EDGE (1 point edge) or a 2P-EDGE (2 point edge) in item 2 SELECT
MODE, be sure to select item 4 EDGE DETECT COND (edge detection conditions).
Go to page 9·39.
When you specify a 1P-SCH (1-point search), a 2P-SCH (2-point search), or a 1P-SCH+1P-EDGE (1-
point search + 1-point edge) in item 2 SELECT MODE, be sure to select item select item 3 GRAY-
SCALE COND (gray scale search conditions).
Continued on the following page
[TYPE00-MEAS0]
1SELECT MEAS. TYPE
2COPY :
3INITIALIZATION
4MEAS. PROG. COND
5EVALUATION COND
6NUMERIC CALC COND
7OUTPUT CONDITIONS
8UPPER MENU
· Select MEAS-POSITION-DEVIATE (measuring positional deviation) on the
SELECT MEAS.TYPE line.
[MEASURING COND] (TYPE00-MEAS.0-POS-DEVIATION)
1REGST NO.
0(0~7)
2SELECT MODE
1P-SCH 2P-SCH 1P-EDGE
2P-EDGE 1P-SCH+1P-EDGE
3GRAY-SCALE COND (TO NEXT SUB-MENU)
4EDGE DETECT COND (TO NEXT SUB-MENU)
5UPPER MENU
· Items 2 SELECT MODE, and 4 EDGE DETECT COND are displayed when item
1 REGST NO. is set to YES.
Measurement conditions
1REGST NO.
(registration number)
2
MODE
3GRAY-SCALE COND
(conditions for a gray
scale search)
4EDGE DETECT COND
(condi-tions for edge
detection)
5UPPER MENU
NO MEAS-POSITION-DEVIATE
EXEC TYPE00 CMR1DIFF.MESURE.
EXEC
(TO NEXT SUB-MENU)
(TO NEXT SUB-MENU)
(TO NEXT SUB-MENU)
(TO NEXT SUB-MENU)
REG.NO YES
First enter the REGST NO. (registration number) from 0 to 7, then chose
YES or NO, depending on whether you wish to record that selection.
Select a mode.
· Enter a mode for each registration number.
When only a gray scale search is being used: 1-point search/ 2-point
search
When only edge detection is being used: 1-point edge/ 2-point edge
When edge detection is being used with a gray scale search: 1-point
search + 1-point edge
· When using edge detection, try to limit variations in the brightness at
the perimeter of the workpieces by manipulating things like the lighting.
Set the conditions for a gray scale search in the next menu.
Set the conditions for edge detection in the next menu.
This will return you to the [TYPE00-MEAS0] (object type - measurement
0) menu.
9-36
Indicates that the object type
00 is selected.
Setting details