Product Dimensions; Anti-Tip Bracket; Before You Start - Whirlpool 30'' Installation Instructions Manual

30" (76.2 cm) or 24" (61 cm) electric freestanding range

Advertisement

Available languages

Available languages

Before you start...

Your safety and the safety of others
are very important.
We have provided many important safety messages
in this manual and on your appliance. Always read
and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards
that can kill or hurt you and others.
All safety messages will follow the safety alert symbol
and either the word "DANGER" or "WARNING."
These words mean:
DANGER
You can be killed or seriously injured if you don't
immediately follow instructions.
WARNING
You can be killed or seriously injured if you don't
follow instructions.
All safety messages will tell you what the potential
hazard is, tell you how to reduce the chance of injury,
and tell you what can happen if the instructions are
not followed.
When installing a cooktop under existing cabinets and the
installation does not meet the minimum cabinet
clearances, install a range hood above the cooktop to
avoid burn hazards.
IMPORTANT: Observe all governing codes and
ordinances. Failure to meet codes and ordinances could
lead to fire or electrical shock.
Read electrical and carpentry instructions.
Proper installation is your responsibility. A qualified
technician must install this range. Make sure you have
everything necessary for correct installation. It is the
customer's responsibility to make sure that the installation
clearances specified on the model/serial rating plate are
met. The model/serial rating plate is located on the frame
behind the drawer.
Check location where range will be installed. The range
should be located for convenient use in the kitchen.
Recessed installations must provide complete enclosure
of the sides and rear of range.
All openings in the wall or floor where range is to be
installed must be sealed.
IMPORTANT: Some cabinet and building materials are
not designed to withstand the heat produced by the oven
for baking and self-cleaning. Check with your builder or
cabinet supplier to make sure that the materials used will
not discolor, delaminate or sustain other damage.
Cutout shown is for a 25-inch (63.5 cm) countertop with a
24-inch (61 cm) base cabinet.
Cabinet constructions: This appliance is designed for use
in a base cabinet with a depth of 24 inches (61 cm). The
maximum depth for overhead cabinets is 13 inches
(33 cm). For the minimum vertical clearance between the
cooking surface and the overhead cabinets, see
NOTE***. Overhead cabinets installed at either side of
the appliance must be a minimum of 18 inches (45.7 cm)
above the cooking surface. The minimum horizontal
distance between the overhead cabinets is 30 inches
(76.2 cm).
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and
in conformance with National Electrical Code,
ANSI/NFPA 70 — latest edition*, or CSA Standard
C22.1, Canadian Electrical Code, Part 1 — latest
edition**, and all local codes and ordinances.
Do not pinch the power supply cord between the range
and the wall.
Do not seal range to side cabinets.
Panel A
Cabinet opening dimensions
25" (63.5 cm) countertop depth
24" (61 cm) base cabinet depth
36" (91.4 cm) countertop height
18" (45.7 cm)
upper cabinet
to countertop
IMPORTANT: Observe all governing
codes and ordinances.
Earthed/grounded electrical outlet is
required.
Cabinet opening dimensions that are
shown must be used.

Product dimensions

26-3/8" (67 cm)
depth with handle
26-5/8" (67.6 cm)
for stainless steel
handle (on some
models)
24-1/2"
(62.2 cm)
Mobile home installation
The installation of this range must conform to the
Manufactured Home Construction and Safety
Standards, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD, Part 280); or when such
standard is not applicable, the Standard for
Manufactured Homes Installations (Manufactured
Home Sites, Communities and Setups), ANSI
A225.1/NFPA 501A, or with local codes*.
In Canada, the installation of this range must conform
with the current standard CAN/CSA-Z240 — latest
edition**, or with local codes.
When this range is installed in a mobile home, it must
be secured to the floor during transit. Any method of
securing the range is adequate as long as it conforms
to the standards listed above.
Four-wire power supply cable must abe used in a
mobile home installation. The appliance wiring will
need to be revised.
Copies of the standards listed may be obtained from:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
13" (33 cm) max.
upper cabinet depth
opening width-
For a 30" (76.2 cm) range:
31" (78.7 cm)
For a 24" (61 cm) range:
25" (63.5 cm)
wall receptacle or junction
4" (10.2 cm)
box - 8" (20.3 cm) to 22"
min. clearance
(55.9 cm) from either
from both sides
cabinet, 7" (17.8 cm) max.
of range to side
from floor.
wall or other
combustible
material.
7/8" (2.2 cm) min.
required between
cutout and cabinet
door or hinge.
30" (76.2 cm) width for
30" (76.2 cm) range
****24" (61 cm) width for
24" (61 cm) range
*** NOTE: 24" (61 m) min. when bottom of wood or metal
cabinet is protected by not less than 1/4" (0.64 cm)
flame retardant millboard covered with not less than No.
28 MSG sheet steel, 0.015" (0.4 mm) stainless steel,
0.024" (0.6 mm) aluminum or 0.020" (0/5 cm) copper.
30" (76.2 cm) min. clearance between the top of the
cooking platform and the bottom of an unprotected
wood or metal cabinet.
**** NOTE: This dimension is for the 24" (61 cm) model.

Anti-tip bracket:

For minimum
clearance to the
top of the
cooktop, see
NOTE.***
46-13/16"
(118.9 cm)
overall
height
36"
(91.4 cm)
cooktop
height
The floor anti-tip bracket must
be installed. To install the anti-
tip bracket shipped with the
range, see Panel B and the anti-
tip bracket template.