en | Connection
6.2

Auxiliary power connector

Caution!
The Low Voltage power supply unit must comply with EN/UL
!
60950. The power supply must be a SELV-LPS unit or a SELV -
Class 2 unit (Safety Extra Low Voltage - Limited Power Source).
Caution!
This device must be connected to earth (ground).
!
Safety (power) ground is indicated by the
Earth
Connect a SELV-LPS or a SELV Class 2 power supply with a
rated supply voltage of 24 VAC or 12 VDC as follows:
2014.04 | v1.0 | AM18-Q0674
4
5
6
|
4
5
6
D
A
A
L
T
A
A
R
M
1
2
3
|
1
2
3
- +
12VDC
24VAC
CVBS
Use AWG16 to 22 stranded wire or AWG16 to 26 solid wire;
cut back 5 mm (0.2 in) of insulation.
Connect the earth terminal of the camera to the system
earth of the installation to ensure correct safety and
EMC/RFI protection.
Loosen the screws of the supplied 2-pole connector and
insert the wires, before tightening the screws again.
Insert the 2-pole connector into the camera power socket.
E
T
H
-
P
o
E
MENU
DINION IP 7000 HD
symbol.
5 mm