Download Print this page
Philips Selecon ACCLAIM FRESNEL Operation Manual

Philips Selecon ACCLAIM FRESNEL Operation Manual

Advertisement

Quick Links

THANK YOU FOR PURCHASING A SELECON LUMINAIRE. WE HAVE DESIGNED THIS LUMINAIRE TO
PROVIDE YOU WITH A SUPERIOR FITTING IN PERFORMANCE, DESIGN AND ENGINEERING. WE ARE
CONFIDENT THAT IT WILL PERFORM TO YOUR EXPECTATIONS FOR MANY YEARS TO COME.
Before operating your new luminaire please read this information to assist you in making maximum use of your
luminaire, its maintenance and care.
If you would like further assistance contact your Selecon dealer or Selecon.
LAMPING YOUR LUMINAIRE
Before lamping – DISCONNECT THE LUMINAIRE FROM THE POWER SUPPLY. Be aware also that the
lamp or luminaire may still be hot, so exercise the necessary caution to avoid burns. Please note also
that these luminaires are not suitable for mounting on a normally flammable surface.
The Selecon Acclaim Fresnel and PC range is designed for use with either the T/25 500W or T/27 650W or the
FRK 650W lamp.
To fit the lamp:
♦ Release the clip fastener and swing down the rear door.
♦ Insert lamp taking care not to touch the quartz envelope with your fingers.
♦ Close door and lock off the fastener.
The luminaire should be at least 1.5m / 5ft away from the nearest object it is lighting.
© June 2009 All Rights Reserved
ACCLAIM FRESNEL AND PC
OPERATION MANUAL
IMPORTANT
NOTE:
discarding the packaging ensure
you have the suspension bolt set,
colour frame, lampbase spacers
&/or the lamp.
Before

Advertisement

loading

Summary of Contents for Philips Selecon ACCLAIM FRESNEL

  • Page 1 Please note also that these luminaires are not suitable for mounting on a normally flammable surface. The Selecon Acclaim Fresnel and PC range is designed for use with either the T/25 500W or T/27 650W or the FRK 650W lamp.
  • Page 2: Mounting Your Luminaire

    MOUNTING YOUR LUMINAIRE Your luminaire uses a theatre lamp with a grid filament. To avoid premature lamp failure it is essential that the luminaire is always mounted so the yoke is horizontal and with the lamp base down, i.e. the lamp adjustment knob is at the bottom of the rear lamp plate.
  • Page 3: Earth Test Point

    Please note that as the handles on the Acclaim range can reach high temperatures depending on the position or orientation of the luminaire, and that gloves should always be worn when focusing these luminaires. ACCESSORIES ♦ Suspension hook clamp (Order Code: 20HC) ♦...
  • Page 4: Physical Data (Fresnel) - Us

    LAMPS: 220V-240V 500W T/25, T/18 11,000 lumens 400hrs average life 500W M40 10,000 lumens 2000hrs average life 650W T/26, T/27 14,500 lumens 600hrs average life Tests conducted using a standard T27, 650W, 240V, 15,000 lumens lamp. PHYSICAL DATA (Fresnel) - US Weight: 7lb 4oz Packed: 8lb...
  • Page 5: Physical Data (Pc) - Us

    LAMPS: 220V-240V 500W T/25, T/18 11,000 lumens 400hrs average life 500W M40 10,000 lumens 2000hrs average life 650W T/26, T/27 14,500 lumens 600hrs average life Tests conducted using a standard T27, 650W, 240V, 15,000 lumens lamp. PHYSICAL DATA (PC) - US Weight: 7lb 12oz Packed: 8lb 8oz...
  • Page 6: Selecon Distributor Network

    The Selecon dealer network is an international group of lighting professionals throughout Australasia, Asia, United Kingdom and Europe, North and South America. Manufacturer: Philips Selecon, 19-21 Kawana Street, Northcote 0627, Auckland, New Zealand Ph: +64 9 481 0100 Fax: +64 9 481 0101 www.seleconlight.com...

This manual is also suitable for:

Seleconacclaim pc