Specifications - Bosch DS484Q Installation Instructions Manual

Quad beam photoelectric detectors
Table of Contents

Advertisement

.

8.0 Specifications

Table 11:
DS484Q and DS486Q Specifications
Alarm Output
Beam Interrupt Time
Selectable Beams
Environmental Discrimination Circuit Output
Maximum Coverage
Material
Dimensions (HxWxD)
Total Weight
Operating Temperature
IP Rating
Location
Pattern Pointability
Voltage
Current Draw
Backup Power Requirements
Temper Output
Trigger Response Time
Bosch Security Systems, Inc. | 7/05 | 4998138530F
DS484Q/DS486Q | Installation Instructions | 8.0
Alarm
Form C 0.2 A @ 30 VDC
Output Period: 3 sec
EDC
NC 0.2 A @ 30 VDC
Output Period: 3 sec
Tamper
NC 0.1 A @ 30 VDC
Output Period: While the cover is removed
Adjustable from 50 ms to 500 ms
Two Groups by four Channels
Normally-closed contacts rated at 0.2 A @ 30
VDC
Outdoor
DS484Q
DS486Q
Indoor
DS484Q
DS486Q
Enclosure Design
Polycarbonate
35 cm x 10 cm x 11 cm
(13.75 in. x 4 in. x 4.1 in.)
Receiver
1.2 kg (2.64 lb)
Transmitter
1.2 kg (2.64 lb)
Environmental Considerations
-25° C to + 55° C
(-13°F to + 130° F)
IP 54 (protection against dust; protection against
splashing water)
Mounting
Surface or pole mount
±90° horizontal, ±10° vertical
Power Requirements
10.5 VDC to 28 VDC non-polarized
Receiver
80 mA standby, 50 mA alarm
Transmitter
DS484Q
DS486Q
4 hours (120 mAh) minimum required for
UL Certificated Installations
Normally-closed contacts rated at 0.1 A @ 30 VDC
Selectable response time of 35 ms to 700 ms
120 m (400 ft)
200 m (660 ft)
240 m (800 ft)
300 m (1000 ft)
35 mA
55 mA
Specifications
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds486q

Table of Contents