Troubleshooting
Guide (cont'd)
Operational
Conditions
RUMBLING
NOISE
In some water areas, scale or mineral
deposits will build up on
your heating elements.
This buildup
will cause a rumbling
noise.
Follow "Element
Cleaning/Replacement"
instructions
to clean
and replace the elements.
• Replace the insulation
block so that it completely
covers the
thermostat and element.
• Replace the access panel.
• Turn "ON" electric power to the water heater.
HIGH
TEMPERATURE
SHUT
OFF
SYSTEM
The water heater
has a high limit shut off system with a reset
button located in the upper thermostat.
Follow the resetting
instructions
which
refer to the high limit
behind the upper access panel.
A CAUTION
If the high limit must be reset again, call Sears Service I
Department
to find out why the high limit turned "OFF"
the e ectr c power•
NOT
ENOUGH
OR NO HOT WATER
NOTE_ If your water heater is connected to an "OFF PEAK"
clock, and uses the
3 wire lead" wiring diagram in the
"Wiring Diagram" section, then the water heater will have a
hi-limit
on both the upper and lower thermostats.
Follow
the instructions to reset the hi-limit behind the upper and
lower access panels.
• Before beginning,
turn "OFF"
electrical power supply to the
water heater.
AWARNING
HAZARD
OF ELECTRICAL
SHOCK!
Before removing
any access panels or servicing the water
heater, make
I sure the electrical supply to the water heater is turned
I "OFF".
Failure to do this could result in DEATH,
SERI-
I OUS BOD LY INJURY, OR PROPERTY
DAMAGE.
• Remove the two screws securing the access panel and remove
panel.
• Remove the insulation
block to expose the opening.
• Reset the high limit by pushing
in the red button
marked
"RESET".
O'1
@
rm_r
ber_
eEnv_
RESET BUTTON
In a new installation,
the water heater may not be properly
connected.
Make sure the cold water supply valve is open.
Review
and check piping
installation.
Make sure that the
cold water line is connected
to the cold water inlet to the
water heater and the hot water line to the hot water outlet
on the water heater.
Make sure the electrical supply to your water heater is
"ON".
Check for loose or blown fuses in your water heater circuit.
Circuit breakers weaken with age and may not handle their
rated load and should be replaced.
Make certain the disconnect
switch, if used, is in the "ON"
position.
Check to see the electric service to your house has not been
interrupted. If this is the case, contact the electric company.
Are the thermostats
set to the desired
temperature?
See
"Temperature
Regulation" section.
If you had experienced very hot water and now no hot water,
the problem may be due to the high temperature
shut off
system.
See "High
Temperature
Shut
Off System"
in
the "Troubleshooting"
section.
During very cold weather, the incoming
water will also be
colder and it will require a longer time to become heated.
The hot water usage may exceed the capacity of the water
heater. If so, wait for water heater to recover after abnormal
demand.
Also examine pipes and faucets for possible water
leaks.
If you can not determine
the problem, then call the Sears
Service Department.
WATER
IS TOO
HOT
Adjust
the thermostat
to a lower setting.
See the "Temperature
Regulation"
section.
22